Extending industrial applicability of TDR liquid level monitoring through flexible probes

@article{Cataldo2013ExtendingIA,
  title={Extending industrial applicability of TDR liquid level monitoring through flexible probes},
  author={Andrea Cataldo and Giuseppe Cannazza and Egidio De Benedetto and Emanuele Piuzzi},
  journal={2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)},
  year={2013},
  pages={850-854}
}
In the present work, an alternative probe configuration to be used for time domain reflectometry (TDR)-based monitoring of liquid level inside tanks is presented. The proposed probe, which resorts to a bifilar transmission line configuration, is flexible and adaptable to the surface of the containers to be monitored. This feature, along with the other advantageous characteristics of TDR, makes this probe configuration particularly attractive for industrial applications. In this paper, to test… CONTINUE READING