Experimental verification of the linear current transformer model

@article{Chau2008ExperimentalVO,
  title={Experimental verification of the linear current transformer model},
  author={G.S.S. Chau and Stefan Ziegler and H. H. C. Iu and Hamdan Daniyal},
  journal={2008 Australasian Universities Power Engineering Conference},
  year={2008},
  pages={1-6}
}
One of the most typical representations of the current sense transformer model is the linear model, comprising an ideal transformer, magnetizing inductance and distributed winding capacitance. The magnetizing inductance models the magnetization of the core based on the assumption of a linear relation between the magnetic H and B field. However in reality, the core material exhibits hysteretic and non-linear behaviour, and the magnetizing current can only be evaluated using hardware experiments… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-4 of 4 references

and L

  • S. Ziegler, R. C. Woodward, H.H.C. Iu
  • J. Borle, "Current Sensing Techniques: A Review…
  • 2008
1 Excerpt

Elements of Electromagnetics

  • M.N.O. Sadiku
  • 3rd Edition. New York: Oxford University Press
  • 2001
1 Excerpt

Similar Papers