Exhaled nitric oxide monitoring by quantum cascade laser: comparison with chemiluminescent and electrochemical sensors.

@article{Mandon2012ExhaledNO,
  title={Exhaled nitric oxide monitoring by quantum cascade laser: comparison with chemiluminescent and electrochemical sensors.},
  author={Julien Mandon and Marieann H{\"o}gman and Peter J.F.M. Merkus and Jan G.C. van Amsterdam and Frans J. M. Harren and Simona M. Cristescu},
  journal={Journal of biomedical optics},
  year={2012},
  volume={17 1},
  pages={
          017003
        }
}
Fractional exhaled nitric oxide (F(E)NO) is considered an indicator in the diagnostics and management of asthma. In this study we present a laser-based sensor for measuring F(E)NO. It consists of a quantum cascade laser (QCL) combined with a multi-pass cell and wavelength modulation spectroscopy for the detection of NO at the sub-part-per-billion by volume (ppbv, 110(-9)) level. The characteristics and diagnostic performance of the sensor were assessed. A detection limit of 0.5 ppbv was… 

Figures and Tables from this paper

Quantum cascade laser-based sensor for detection of exhaled and biogenic nitric oxide
A sensor based on a continuous wave quantum cascade laser, operating near 5.2 μm, in combination with integrated cavity output spectroscopy has been developed for simultaneous measurement of nitric
Laser-based methods for sensitive trace gas detection
A sensor based on a continuous wave quantum cascade laser, operating near 5.2 μm, in combination with integrated cavity output spectroscopy has been developed for simultaneous measurement of nitric
Pressure optimization of an EC-QCL based cavity ring-down spectroscopy instrument for exhaled NO detection
Nitric oxide (NO) in exhaled breath has gained increasing interest in recent years mainly driven by the clinical need to monitor inflammatory status in respiratory disorders, such as asthma and other
Spectroscopic monitoring of NO traces in plants and human breath: applications and perspectives
Optical methods based on quantum cascade lasers (QCLs) are becoming popular in many life science applications. We report on two trace gas detection schemes based on continuous wave QCLs for on-line
Measurement of Exhaled Nitric Oxide in 456 Lung Cancer Patients Using a Ringdown FENO Analyzer
TLDR
Exhaled NO level alone is not a useful clinical tool for identifying lung cancer, but it should be considered when developing a diagnosis model of lung cancer by using breath analysis.
New miniaturized exhaled nitric oxide sensor based on a high Q/V mid-infrared 1D photonic crystal cavity.
A high Q/V mid-infrared 1D photonic crystal cavity in chalcogenide glass AMTIR-1 (Ge33As12Se55) resonating at λR=5.26  μm has been proposed as a key element of a sensor able to evaluate the nitric
Methods of NO detection in exhaled breath.
TLDR
An overview of the currently available methods for monitoring NO in exhaled breath and the use of the modelling of NO production and transport in the lung in clinical practice is presented.
Fractional exhaled nitric oxide-measuring devices: technology update
TLDR
The cost effectiveness and ability to achieve adequate flexibility in sensitivity and selectivity of NO measurement for these methods are evaluated alongside the potential for use of laser-based technology.
Part per trillion nitric oxide measurement by optical feedback cavity-enhanced absorption spectroscopy in the mid-infrared
While nitric oxide (NO) is being monitored in various fields of application, there is still a lack of available instruments at a sub-ppb level of sensitivity. We report on the first application of
Quantitative detection of nitric oxide in exhaled human breath by extractive electrospray ionization mass spectrometry
TLDR
The application of EESI-MS is extended to small molecules with low proton affinity and collision-induced dissociation efficiency, which are usually poorly visible by conventional ion trap mass spectrometers, which opens new possibilities for the research of human metabolism and clinical diagnosis.
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 54 REFERENCES
Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy.
TLDR
The off-axis ICOS sensor measurements are in good agreement with the data acquired with the two commercial gas analyzers, demonstrating the performance characteristics and merits of mid-infrared spectroscopy for exhaled breath analysis.
Determination of exhaled nitric oxide distributions in a diverse sample population using tunable diode laser absorption spectroscopy
A liquid-nitrogen free mid-infrared tunable diode laser absorption spectroscopy (TDLAS) system equipped with a folded-optical-path astigmatic Herriott cell was used to measure levels of exhaled
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
TLDR
The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care and shows good repeatability, and it can be used successfully on adults and most children.
Ultrasensitive detection of nitric oxide at 5.33 μm by using external cavity quantum cascade laser-based Faraday rotation spectroscopy
TLDR
A transportable prototype Faraday rotation spectroscopic system based on a tunable external cavity quantum cascade laser has been developed for ultrasensitive detection of nitric oxide (NO) and results of continuous, unattended monitoring of atmospheric NO concentration levels are reported.
Portable exhaled nitric oxide measurement: Comparison with the "gold standard" technique.
TLDR
FENO values obtained using a portable analyzer correlate well with those obtained using an established laboratory analyzer and can be used to discriminate asthmatic from nonasthmatic patients.
Measurement of Exhaled Nitric Oxide in a General Population Sample: A Comparison of the Medisoft HypAir FENO and Aerocrine NIOX Analyzers
TLDR
FENO measurements obtained with the HypAir FENO correlated well with the NIOX, but were approximately 1.6 times higher; a conversion factor is required if results are to be compared with theNIOX instrument.
Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser.
TLDR
A spectroscopic gas sensor for nitric oxide (NO) detection based on a cavity ringdown technique was designed and evaluated and future improvements are discussed that would allow quantification of NO in human breath.
Laser-based systems for trace gas detection in life sciences
Infrared gas phase spectroscopy is becoming very common in many life science applications. Here we present three types of trace gas detection systems based on CO2 laser and continuous wave (cw)
Spectroscopic detection of biological NO with a quantum cascade laser
Abstract.Two configurations of a continuous wave quantum cascade distributed feedback laser-based gas sensor for the detection of NO at a parts per billion (ppb) concentration level, typical of
...
1
2
3
4
5
...