Evidence for the distortion product frequency place as a source of distortion product otoacoustic emission (DPOAE) fine structure in humans. II. Fine structure for different shapes of cochlear hearing loss.

Abstract

Distortion product otoacoustic emissions (DPOAE) were recorded from eight human subjects with mild to moderate cochlear hearing loss, using a frequency spacing of 48 primary pairs per octave and at a level L1 = L2 = 60 dBSPL and with a fixed ratio f2/f1. Subjects with different shapes of hearing thresholds were selected. They included subjects with near… (More)

Topics

Figures and Tables

Sorry, we couldn't extract any figures or tables for this paper.

Slides referencing similar topics