Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175.

@article{OBrien1996EvaluationOT,
  title={Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175.},
  author={O'Brien and Mee and Atkins and Thomas},
  journal={Blood pressure monitoring},
  year={1996},
  volume={1 1},
  pages={55-61}
}
OBJECTIVE: We evaluated three devices for self-measurement of blood pressure - the Omron HEM-705CP, the Philips HP5332 and the Nissei DS-175 - according to the revised protocol of the British Hypertension Society (BHS). The results were also analysed according to the criteria for accuracy of the revised standard of the Association for the Advancement of Medical Instrumentation (AAMI). DESIGN: The revised BHS protocol is divided into two parts. Part I, the part applicable to this study… CONTINUE READING