Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.

@article{Tamatani2002EvaluationOT,
  title={Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.},
  author={Shinichi Tamatani and Yasushi Ito and Hiroshi Abe and Tetsuo Koike and Shigekazu Takeuchi and Ryuichi Tanaka},
  journal={AJNR. American journal of neuroradiology},
  year={2002},
  volume={23 5},
  pages={762-7}
}
BACKGROUND AND PURPOSE The long-term outcome of aneurysmal coil embolization has not been determined. We retrospectively analyzed the results of our cases treated with detachable coils and evaluated the long-term stability of embolized aneurysms. METHODS This study involved 100 aneurysms in 93 patients who underwent follow-up angiography > or = 3 months after initial treatment between December 1993 and December 1999. The percentage of the coil volume occupying the aneurysm lumen (embolized… CONTINUE READING