Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation.

@article{Chow2008EvaluationOT,
  title={Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation.},
  author={James C. L. Chow and Michael K. K. Leung and Mohammad K. Islam and Bernhard D Norrlinger and David Anthony Jaffray},
  journal={Medical physics},
  year={2008},
  volume={35 1},
  pages={52-60}
}
The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnr code for 100, 120, 130, and… CONTINUE READING