Evaluation of differential pressure setpoint of chilled water pumps in cleanroom HVAC systems for energy savings in high-tech industries

@article{Su2012EvaluationOD,
  title={Evaluation of differential pressure setpoint of chilled water pumps in cleanroom HVAC systems for energy savings in high-tech industries},
  author={Chun-Lien Su and Kuen-Tyng Yu},
  journal={48th IEEE Industrial & Commercial Power Systems Conference},
  year={2012},
  pages={1-9}
}
Variable frequency speed control technologies are widely used in chilled water pumps in cleanroom heating, ventilation and air conditioning (HVAC) systems in high-tech industries to reduce energy consumption. Pumps with variable frequency drivers work based on the reading from the differential pressure sensor placed between the chilled water supply and return lines before the secondary and tertiary pumps. Determination of the differential pressure setpoint must take pipeline topology and… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-9 of 9 references

An energy consumption and management mode study in a high-tech factory

  • S. K. Lee, W. L. Chen
  • Journal of Science and Engineering Technology…
  • 2009
1 Excerpt

Comparison of pipe flow formulas and head losses in fittings

  • R. Pitt, S. Clark
  • Technical Presentation Report, December 2008…
  • 2008
2 Excerpts

Energy evaluation of optimal control strategies for central VWV chiller systems

  • X. Q. Jin, Z. M. Du, X. K. Xiao
  • Applied Thermal Engineering, 2007.
  • 2007
1 Excerpt

Optimize pump speed control using pump water flow station for HV AC Systems

  • G. P. Liu, M. S. Liu, G. Wang
  • ASHRAE Transactions, 2007, pp. 362-367.
  • 2007
1 Excerpt

Global optimization for overall HV AC systems-Part I, problem formulation and analysis

  • L. Lu, W. Cai, Y. C. Soh, L. Xie
  • Energy Conversion and Management, Vol. 46, 2005…
  • 2005
1 Excerpt

Global optimization for overall HV AC systems-Part II, problem solution and simulations

  • L. Lu, W. Cai, Y. C. Soh, L. Xie
  • Energy Conversion and Management, Vol. 46, 2005…
  • 2005
1 Excerpt

A simplified modeling of cooling coils for control and optimization of HVAC systems

  • Y. W. Wang, W. 1. Cai, Y. C. Soh, S. 1. Li, L. Lu, L. Xie
  • Energy Conversion and Management, Vol. 45, 2004…
  • 2004
1 Excerpt

Pump differential pressure setpoint reset based on chilled water valve position

  • B. 1. Moore, D. S. Fisher
  • ASHRAE Transactions, 2003, pp. 373-379.
  • 2003
1 Excerpt

Handbook of Hydraulics (7th ed.)

  • E. F. Brater, H. W. King, J. E. Lindell, C. Y. Wei
  • Mc Graw Hill, Inc.,
  • 1996
1 Excerpt

Similar Papers