Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome.

@article{MunguaIzquierdo2012EvaluationOA,
  title={Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome.},
  author={Diego Mungu{\'i}a-Izquierdo and Alfredo Santalla and Alejandro Legaz-Arrese},
  journal={Archives of physical medicine and rehabilitation},
  year={2012},
  volume={93 1},
  pages={
          115-22
        }
}

Figures and Tables from this paper

Validity and reliability of rating perceived exertion in women with fibromyalgia: exertion-pain discrimination
TLDR
The main findings suggest that the Borg CR-10 scale is valid and moderately reliable for monitoring exercise intensity in women with FM, and these patients were able to discriminate between exertion and exercise-induced pain.
Comparison of the International Physical Activity Questionnaire (IPAQ) with a multi-sensor armband accelerometer in women with fibromyalgia: the al-Ándalus project.
TLDR
The IPAQ differs from objectively measured PA and presents limitations to classify different categories of PA based on SWA data, and is not a reliable tool to assess PA in women with fibromyalgia.
Association of cardiorespiratory fitness with pressure pain sensitivity and clinical pain in women with fibromyalgia
TLDR
It is suggested that CRF is associated with pressure pain sensitivity but not with clinical pain in women with FM, and further longitudinal and intervention studies are needed to determine whether CRF could be involved in some mechanisms of pain processing.
Inter-accelerometer comparison to measure physical activity and sedentary time in female fibromyalgia patients: the al-Ándalus project.
TLDR
The present study showed that the SWA and the Actigraph provide different estimates of PA and sedentary time in Spanish female fibromyalgia patients, suggesting that the PA levels and Sedentary time provided by both devices should be interpreted independently across studies.
Measuring Habitual Physical Activity in Neuromuscular Disorders: A Systematic Review
TLDR
A checklist of considerations for the assessment and reporting of HPA in NMD is proposed, and the variety and heterogeneity of tools and methods in the published literature makes the comparison across different studies difficult, and methodological guidelines are warranted.
Spanish adaptation and psychometric properties of the Sedentary Behaviour Questionnaire for fibromyalgia patients: the al-Andalus study.
TLDR
The SBQ-S developed in this study presents a good reliability and poor convergent validity when compared with the SWA in the Spanish fibromyalgia patients studied.
Validity of activity monitors in health and chronic disease: a systematic review
TLDR
Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.
Objective Assessment of Upper-Limb Mobility for Poststroke Rehabilitation
TLDR
A novel single-index-based assessment approach for quantitative upper-limb mobility evaluation has been proposed for poststroke rehabilitation and has suggested that the proposed assessment index can not only differentiate the levels of limb function impairment clearly, but also strongly correlate with the Brunnstrom stages of recovery.
Predicting Free-Living Energy Expenditure Using a Miniaturized Ear-Worn Sensor: An Evaluation Against Doubly Labeled Water
TLDR
It is demonstrated that laboratory-derived prediction models can be used to predict EE under free-living conditions and against those derived from doubly labeled water.
...
...

References

SHOWING 1-10 OF 60 REFERENCES
Validity of a multi-sensor armband in estimating rest and exercise energy expenditure.
TLDR
The SWA provided valid and reliable Estimates of EE at rest and generated similar mean estimates of EE as IC on the ergometer; however, individual error was large and the SWA overestimated the EE of flat walking and underestimated inclined walking EE.
Comparison of pedometer and accelerometer measures of free-living physical activity.
TLDR
Differences in mean steps per day detected may be due to differences in set instrument sensitivity thresholds and/or attachment, and additional studies with different populations are needed to confirm a recommended number of Steps per day associated with the duration and intensity of public health recommendations for ambulatory activity.
Measuring energy expenditure in cardiac patients using the Body Media Armband versus indirect calorimetry. A validation study.
TLDR
The accuracy of the BodyMedia SenseWear Armband appears to be exercise modality dependent in those with heart disease when using software developed for the general population, therefore, the information should be interpreted cautiously, particularly during treadmill walking and rowing.
Exercise in warm water decreases pain and improves cognitive function in middle-aged women with fibromyalgia.
TLDR
An exercise therapy three times per week for 16 weeks in a warm-water pool is an adequate treatment to decrease the pain and severity of FM well as to improve cognitive function in previously unfit women with FM and heightened painful symptomatology.
Comparison of activity monitors to estimate energy cost of treadmill exercise.
TLDR
The CSA was the best estimate of total EE at walking and jogging speeds, the TriTrac-R3D was thebest estimate oftotal EE at running speeds, and the SenseWear Armband was theBest estimate ofTotal EE at most speeds.
Ambulatory monitoring of physical activity and symptoms in fibromyalgia and chronic fatigue syndrome.
TLDR
Patients with FM and/or CFS engaged in less high-intensity physical activities than that recorded for sedentary control subjects, and reduced peak activity was correlated with measures of poor physical function.
Effects of lifestyle physical activity on perceived symptoms and physical function in adults with fibromyalgia: results of a randomized trial
TLDR
Accumulating at least 30 minutes of LPA throughout the day produces clinically relevant changes in perceived physical function and pain in previously minimally active adults with FM.
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure.
TLDR
The results suggest that there are limitations to using triaxial accelerometry to quantify energy expenditure, and that energy expenditure estimated via TriTrac-R3D does not increase with increasing workloads.
A new device for measuring resting energy expenditure (REE) in healthy subjects.
Validity and reliability of community health activities model program for seniors and short-form international physical activity questionnaire as physical activity assessment tools in patients with fibromyalgia
TLDR
In a fibromyalgia population, the s-IPAQ does not appear to be a reliable and valid PA assessment tool and there is a need to develop new measures or validate other existing well-established PA questionnaires.
...
...