Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.

@article{Hodovi2004EvaluationOF,
  title={Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.},
  author={Iljaz Hod{\vz}ovi{\'c} and Ian Peter Latto and Antony Robert Wilkes and Judith E. Hall and William W. Mapleson},
  journal={Anaesthesia},
  year={2004},
  volume={59 8},
  pages={
          811-6
        }
}
In a randomised cross-over study, 48 anaesthetists attempted to place a Frova single-use introducer, an Eschmann multiple-use introducer and a Portex single-use introducer in the trachea of a manikin set up to simulate a grade 3 laryngoscopic view. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). Successful placement (proportion, 95% confidence interval) of either the Frova introducer (65%, 50-77%) or the Eschmann introducer (60%, 46-73%) was… CONTINUE READING

Figures, Tables, and Topics from this paper.

Citations

Publications citing this paper.
SHOWING 1-10 OF 25 CITATIONS

A comparative randomized trial of intubation success in difficult intubation cases: the use of a Frova intubation catheter versus a Bonfils intubation fiberoscope

VIEW 1 EXCERPT
CITES METHODS

The role of tracheal tube introducers and stylets in current airway management

VIEW 1 EXCERPT
CITES BACKGROUND

References