Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent: 4-year results of the PROTECT randomized trial.

@article{Wijns2014EndeavourZS,
  title={Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent: 4-year results of the PROTECT randomized trial.},
  author={William Wijns and Philippe Gabriel Steg and Laura Mauri and Volkhard Kurowski and Keyur H Parikh and Run-lin Gao and Christoph Bode and John P. Greenwood and Erik Lip{\vs}ic and Farqad Alamgir and Tessa A M Rademaker-Havinga and Eric Boersma and Peter Walter Radke and Frank N van Leeuwen and Edoardo Camenzind},
  journal={European heart journal},
  year={2014},
  volume={35 40},
  pages={2812-20}
}
AIMS To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable stent thrombosis or in the other main secondary clinical outcomes consisting of the composite of death or myocardial infarction (MI). Prespecified 4-year clinical follow-up was analysed. METHODS… CONTINUE READING
Related Discussions
This paper has been referenced on Twitter 5 times. VIEW TWEETS

Citations

Publications citing this paper.
Showing 1-10 of 15 extracted citations

Very Late Scaffold Thrombosis: Intracoronary Imaging and Histopathological and Spectroscopic Findings.

Journal of the American College of Cardiology • 2015
View 11 Excerpts
Highly Influenced

Efficacy Over Time With Drug-Eluting Stents in Saphenous Vein Graft Lesions.

Journal of the American College of Cardiology • 2018
View 2 Excerpts

References

Publications referenced by this paper.
Showing 1-10 of 26 references

Comparison of 4 year results of the PROTECT randomized trial

PW Serruys, S Silber, +22 authors S. Windecker
N Engl J Med • 2010
View 3 Excerpts

Myocardial infarction adjudication in contemporary all-comer stent trials: balancing sensitivity and specificity. Addendum to the historical MI definitions used in stent studies.

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology • 2010

Similar Papers