End-tidal carbon dioxide

@inproceedings{Vealey2017EndtidalCD,
  title={End-tidal carbon dioxide},
  author={Ryan J Vealey and Laura B. Hemmer},
  year={2017}
}
widely used in the adult and paediatric intensive care setting, and has been found to be an accurate method of estimating PaCO2 in term infants, however, it has not been widely accepted in NICU as it provides only a rough estimation of PaCO2 in infants with significant lung disease. EtCO2 detectors measure the levels of carbon dioxide in exhaled breath. EtCO2 is the carbon dioxide at its maximum level at the end of expiration. A good end-tidal plateau in exhaled PaCO2 usually represents… 

Figures from this paper

Internal carotid artery blood flow in healthy awake subjects is reduced by simulated hypovolemia and noninvasive mechanical ventilation

TLDR
In healthy awake subjects, ICA‐BF was significantly reduced during simulated hypovolemia combined with noninvasive PPV, despite maintained arterial blood pressure, which may cause clinically relevant reductions in CBF.

Post-intubation Management

TLDR
In the prehospital environment the incidence of complications can be expected to be higher as the environment is often less controlled and the patient more unstable (intrahospital transfers usually only take place if patients are relatively stable).

Biofeedback as complementary treatment in patients with epilepsy – an underestimated therapeutic option? Review, results, discussion

TLDR
Four different techniques of biofeedback were used to improve seizure frequency in patients with epilepsy, and three of these techniques, measuring EEG, electrodermal activity or GSR seem to be promising methods for successful seizure control.

References

SHOWING 1-10 OF 28 REFERENCES

Does End-tidal Carbon Dioxide Measurement Correlate with Arterial Carbon Dioxide in Extremely Low Birth Weight Infants in the First Week of Life ?

TLDR
Pulse oximetry provides the non-invasive method of assessing the oxygenation in neonatal intensive care unit (NICU) patients and hypocarbia and hypercarbia are detrimental to the ELBW infants.

Good estimation of arterial carbon dioxide by end‐tidal carbon dioxide monitoring in the neonatal intensive care unit

TLDR
PetCO2 was a valid and reliable method for monitoring PaCO2 in neonates, especially preterm infants and this method decreases blood loss and prevents complications associated with arterial catheters, and is recommend using mainstream capnography to monitor PetCO2 instead of measuring Pa CO2 in the NICU.

End tidal carbon dioxide monitoring—Its reliability in neonates

TLDR
The study showed that ETCO2 correlates closely with PaCO2 in most clinical situations in neonates and the authors recommend its use in all level III NICUs in ventilated babies.

Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport

TLDR
TcPco2 should currently be considered the preferred method of non-invasive CO2 monitoring for neonatal transport because it underestimated Paco2 at a clinically unacceptable level and trended reliably over time within individual subjects.

Agreement of Carbon Dioxide Levels Measured by Arterial, Transcutaneous and End Tidal Methods in Preterm Infants ≤28 Weeks Gestation

TLDR
A moderate agreement with a wide variation in individual values was observed between noninvasive methods and PaCO2 in preterm infants in the first 24 hours.

Are carbon dioxide detectors useful in neonates?

Maintenance of neonatal normocarbia may prevent chronic lung disease and periventricular leucomalacia, but this requires frequent arterial sampling, which has risks. Alternative methods for measuring

End-tidal carbon dioxide monitoring in pediatrics - clinical applications.

  • M. Bhende
  • Medicine
    Journal of postgraduate medicine
  • 2001
TLDR
Clinical applications of end-tidal CO2 monitoring with special reference to the paediatric patient is covered, including secondary confirmation of proper tube placement in all patients by exhaled CO2 immediately after intubation and during transport.

Colorimetric End‐Tidal Carbon Dioxide Monitoring for Tracheal Intubation

TLDR
It is concluded that Colorimetric ETco2 monitoring is a safe, reliable, rapid, simple, and portable method for determining endotracheal tube position for patients who are hemodynamically stable and should be recommended where capnography is not available.

Monitoring of end tidal CO2 in neonatal intensive care.

The use of monitoring end tidal carbon dioxide pressure (PetCO2) in neonatal intensive care was studied in 19 infants with respiratory disease. PetCO2 correlated poorly with arterial pCO2, the

Carbon dioxide kinetics and capnography during critical care

TLDR
Capnography and the measurement of end-tidal partial pressure of carbon dioxide (PETCO2) will gradually be augmented by relatively new measurement methodology, including the volume ofcarbon dioxide exhaled per breath (VCO2,br) and average alveolar expired PCO2 (PǢCO2).