Electricity-Free Amplification and Detection for Molecular Point-of-Care Diagnosis of HIV-1

Abstract

In resource-limited settings, the lack of decentralized molecular diagnostic testing and sparse access to centralized medical facilities can present a critical barrier to timely diagnosis, treatment, and subsequent control and elimination of infectious diseases. Isothermal nucleic acid amplification methods, including reverse transcription loop-mediated isothermal amplification (RT-LAMP), are well-suited for decentralized point-of-care molecular testing in minimal infrastructure laboratories since they significantly reduce the complexity of equipment and power requirements. Despite reduced complexity, however, there is still a need for a constant heat source to enable isothermal nucleic acid amplification. This requirement poses significant challenges for laboratories in developing countries where electricity is often unreliable or unavailable. To address this need, we previously developed a low-cost, electricity-free heater using an exothermic reaction thermally coupled with a phase change material. This heater achieved acceptable performance, but exhibited considerable variability. Furthermore, as an enabling technology, the heater was an incomplete diagnostic solution. Here we describe a more precise, affordable, and robust heater design with thermal standard deviation <0.5°C at operating temperature, a cost of approximately US$.06 per test for heater reaction materials, and an ambient temperature operating range from 16°C to 30°C. We also pair the heater with nucleic acid lateral flow (NALF)-detection for a visual readout. To further illustrate the utility of the electricity-free heater and NALF-detection platform, we demonstrate sensitive and repeatable detection of HIV-1 with a ß-actin positive internal amplification control from processed sample to result in less than 80 minutes. Together, these elements are building blocks for an electricity-free platform capable of isothermal amplification and detection of a variety of pathogens.

DOI: 10.1371/journal.pone.0113693

Extracted Key Phrases

10 Figures and Tables

01020201520162017
Citations per Year

Citation Velocity: 6

Averaging 6 citations per year over the last 3 years.

Learn more about how we calculate this metric in our FAQ.

Cite this paper

@inproceedings{Singleton2014ElectricityFreeAA, title={Electricity-Free Amplification and Detection for Molecular Point-of-Care Diagnosis of HIV-1}, author={Jered Singleton and Jennifer L. Osborn and Lorraine Lillis and Kenneth R Hawkins and Dylan Guelig and W. G. Price and Rachel Johns and Kelly B. Ebels and David S Boyle and Bernhard Weigl and Paul LaBarre}, booktitle={PloS one}, year={2014} }