Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique.
@article{Nie2001EffectsOS, title={Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique.}, author={Xiaoying Nie and Adrian Leyland and Allan Darley Matthews and Jia Chao Jiang and Efsftathios I. Meletis}, journal={Journal of biomedical materials research}, year={2001}, volume={57 4}, pages={ 612-8 } }
Hydroxyapatite (HA) coatings can be deposited using a hybrid process of plasma electrolysis and electrophoresis, called plasma-assisted electrophoretic deposition (PEPD). HA aqueous suspensions with various pH values were prepared using a modified ultrasonic cleaning bath as an agitator/stirrer. Both DC and unbalanced AC power supplies were used to bias the titanium alloy substrate materials employed in this work. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray… CONTINUE READING
Topics from this paper.
Citations
Publications citing this paper.
SHOWING 1-10 OF 14 CITATIONS
Investigation of Plasma Electrolytic Oxidation Processes for Production of Porous Biocompatible Coatings on Ti alloys
VIEW 2 EXCERPTS
CITES BACKGROUND & METHODS
Ion-Doped Silicate Bioceramic Coating of Ti-Based Implant
VIEW 1 EXCERPT
CITES METHODS
Calcium orthophosphate coatings, films and layers
VIEW 2 EXCERPTS
CITES METHODS
The structural and biological properties of hydroxyapatite-modified titanate nanowire scaffolds.
VIEW 1 EXCERPT
CITES BACKGROUND
Electrophoretic deposition of biomaterials.
VIEW 2 EXCERPTS
CITES BACKGROUND & METHODS