Effect of vapor lock on root canal debridement by using a side-vented needle for positive-pressure irrigant delivery.

@article{Tay2010EffectOV,
  title={Effect of vapor lock on root canal debridement by using a side-vented needle for positive-pressure irrigant delivery.},
  author={Franklin R Tay and Li-sha Gu and G. John Schoeffel and Courtney E Wimmer and Lisiane F Susin and Kai Zhang and S. N. Arun and Jongryul Kim and Stephen W. Looney and David Henry Pashley},
  journal={Journal of endodontics},
  year={2010},
  volume={36 4},
  pages={745-50}
}
INTRODUCTION This study examined the effect of vapor lock on canal debridement efficacy by testing the null hypothesis that there is no difference between a "closed" and an "open" system design in smear layer and debris removal by using a side-vented needle for irrigant delivery. METHODS Roots in the closed system were sealed with hot glue and embedded in polyvinylsiloxane to restrict fluid flow through the apical foramen during cleaning and shaping. For the open system, the apical foramen… CONTINUE READING
Highly Influential
This paper has highly influenced 11 other papers. REVIEW HIGHLY INFLUENTIAL CITATIONS
86 Citations
35 References
Similar Papers

Citations

Publications citing this paper.
Showing 1-10 of 86 extracted citations

References

Publications referenced by this paper.
Showing 1-10 of 35 references

Similar Papers