EPR dosimetry using commercial glasses for high gamma doses.

@article{Teixeira2005EPRDU,
  title={EPR dosimetry using commercial glasses for high gamma doses.},
  author={Maria In{\^e}s Teixeira and Gilberto M Ferraz and Linda Viola Ehlin Caldas},
  journal={Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine},
  year={2005},
  volume={62 2},
  pages={365-70}
}
Commercial transparent and colored (bronze, brown, and green) glasses were studied as possible dosimeters for high gamma doses using electronic paramagnetic resonance (EPR). All EPR spectra showed the characteristic Fe3+ signals, g=4.27 and 2.01. The signal at g=2.01 presented a more useable behavior for the calibration curve. All samples showed their usefulness as high dose dosimeters. 