This paper presents the development and application of a new fibre-optics instrumentation system for accurate measurement and analysis of the dynamic air gap behaviour of large hydroelectric generators. The system uses a passive reflective fibre-optics sensor which is immune to EMI and functions correctly on an excited operating generator. Air gap tests were performed on four 184 MV. A, 15.6 m stator bore diameter generators with 16 radial stator support rods. One of these units at B. C. Hydro… CONTINUE READING
13 Citations
2 References
Similar Papers

Citations

Publications citing this paper.
Showing 1-10 of 13 extracted citations

References

Publications referenced by this paper.
Showing 1-2 of 2 references

Corrective action taken on Unit 2 in 1982

  • outward bulging
  • 1982