Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis.

@article{Morgan2005DigitalIO,
  title={Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis.},
  author={James E. Morgan and Nicholas J L Sheen and Rachel V. North and Yee Fong Choong and Ejaz Ansari},
  journal={The British journal of ophthalmology},
  year={2005},
  volume={89 7},
  pages={879-84}
}
AIMS To compare monoscopic and stereoscopic assessment of the optic disc using novel software for the digital stereoscopic analysis of optic disc stereopairs. METHODS Software was developed for the stereoscopic display of digital optic disc images using an interlaced display method. Neuroretinal rim width was determined at 10 degree intervals around the optic disc using a custom (stereoscopic) cursor whose depth was adjusted to that of Elschnig's rim. Measurements were taken, first viewing… CONTINUE READING

From This Paper

Figures, tables, and topics from this paper.

Citations

Publications citing this paper.
Showing 1-10 of 30 extracted citations

References

Publications referenced by this paper.
Showing 1-10 of 29 references

Detection of optic disc change with the Heidelberg retina tomograph before confirmed visual field change in ocular hypertensives converting to early glaucoma

  • DS Kamal, AC Viswanathan, DF Garway-Heath
  • Br J Ophthalmol
  • 1999