Development of high-power density, 4-kV pulse transformers for TWTA

@article{Kim2004DevelopmentOH,
  title={Development of high-power density, 4-kV pulse transformers for TWTA},
  author={S. C. Kim and S. H. Nam and D. H. Kim},
  journal={IEEE Transactions on Plasma Science},
  year={2004},
  volume={32},
  pages={1873-1878}
}
Pulse transformers suitable for high-frequency and high-voltage operations in a traveling-wave tube amplifier (TWTA) had been designed, fabricated, and tested. Two transformers with different operation frequency of 100 and 80 kHz were designed, fabricated, and tested. The transformer with 100-kHz switching frequency had input and output voltages of 250 Vdc and -4.1 kV, respectively. Operating power was 3.06 kW. Achieved power density of the 100-kHz transformers was 22.26 W/cm/sup 3/. The… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-5 of 5 references

Development of a high frequency and high-voltage pulse transformer for a TWT HVPS

  • Proc. 14th Int. Pulsed Power Conf., Dallas, TX…
  • 2003
2 Excerpts

Field analysis of the TWT HVPS transformer and HV module

  • S. C. Kim
  • Proc. IEEE 25th IPMC and 2002 High Voltage…
  • 2002

Optimum design of a high-power high-frequency transformer

  • R. Petkov
  • IEEE Trans. Power Electron., vol. 11, pp. 33–42…
  • 1996
1 Excerpt

Solid-State Power Conversion Handbook

  • P. E. Tarter
  • New York: Wiley,
  • 1993
1 Excerpt

Similar Papers

Loading similar papers…