Development of Cheaper Embryo Vitrification Device Using the Minimum Volume Method

@inproceedings{MarcoJimnez2016DevelopmentOC,
  title={Development of Cheaper Embryo Vitrification Device Using the Minimum Volume Method},
  author={Francisco Marco-Jim{\'e}nez and Estrella Jim{\'e}nez-Trigos and Victoria Almela-Miralles and Jos{\'e} Salvador Vicente and Yann H{\'e}rault},
  booktitle={PloS one},
  year={2016}
}
This study was designed to compare the efficiency of the Cryotop and Calibrated plastic inoculation loop (CPIL) devices for vitrification of rabbit embryos on in vitro development and implantation rate, offspring rate at birth and embryonic and fetal losses. CPIL is a simple tool used mainly by microbiologists to retrieve an inoculum from a culture of microorganisms. In experiment 1, embryos were vitrified using a Cryotop device and a CPIL device. There were no significant differences in… CONTINUE READING