Determination of mangiferin in rat plasma by liquid-liquid extraction with UPLC-MS/MS.

@article{Han2010DeterminationOM,
  title={Determination of mangiferin in rat plasma by liquid-liquid extraction with UPLC-MS/MS.},
  author={Dandan Han and Chengjun Chen and Yu Zhang and Yanjiao Wang},
  journal={Journal of pharmaceutical and biomedical analysis},
  year={2010},
  volume={51 1},
  pages={
          260-3
        }
}
An ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method employing electrospray ionization (ESI) has been developed for the determination of mangiferin in rat plasma using diphenhydramine as the internal standard (IS). Liquid-liquid extraction (LLE) was used for sample preparation and the analysis was achieved with gradient elution on C(18) reversed phase column. The method was validated over the concentration range 0.02-5.0 microg/mL for oral administration and 0… CONTINUE READING
Highly Cited
This paper has 40 citations. REVIEW CITATIONS

Citations

Publications citing this paper.
Showing 1-10 of 18 extracted citations

Metabolism and pharmacokinetics of mangiferin in conventional rats, pseudo-germ-free rats, and streptozotocin-induced diabetic rats.

Drug metabolism and disposition: the biological fate of chemicals • 2012
View 1 Excerpt
Highly Influenced

Bioanalytical method development and validation: Critical concepts and strategies.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences • 2017
View 1 Excerpt