Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient

@article{AntoninoDaviu2011DetectionOB,
  title={Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient},
  author={Jose Alfonso Antonino-Daviu and Martin Riera-Guasp and Joan Pons-Llinares and Jongbin Park and Sang Bin Lee and Jiyoon Yoo and Christian Kral},
  journal={8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives},
  year={2011},
  pages={1-8}
}
Unlike single-cage rotor fault detection, fast Fourier transform (FFT)-based steady-state spectrum analysis techniques can fail to detect outer-cage faults in double-cage induction motors due to the small outer-cage current under running conditions. Double-cage motors are typically employed in applications that require loaded starts. This makes the outer cage vulnerable to fatigue failure since it must withstand the high starting current and long startup time frequently. However, there are only… CONTINUE READING