Design of decoupled controller for TITO system using characteristic ratio assignment

@article{Numsomran2007DesignOD,
  title={Design of decoupled controller for TITO system using characteristic ratio assignment},
  author={Arjin Numsomran and T. Wongkhum and Tianchai Suksri and Phongchai Nilas and Jutarut Chaoraingern},
  journal={2007 International Conference on Control, Automation and Systems},
  year={2007},
  pages={957-962}
}
Most control performances in actual design are usually defined by the time domain response such as overshoot, rising time, settling time, steady state error, etc.. There are few control design methods, which are able to apply directly to the purpose. The pole placement method is the most popular. The Characteristic Ratio Assignment (CRA) is one technique of pole placement based on defined parameter of characteristic equation. This technique can adjustment of speed response and the damping… CONTINUE READING

References

Publications referenced by this paper.
Showing 1-10 of 21 references

Sokolov“Some Sufficient Conditions for Stability and Instability of Continuous Linear Stationary Systems

  • N.I.A.V. Lipatov
  • Translated from Automatika,
  • 1978
Highly Influential
2 Excerpts

A new design method for transient response control ” , presente d at the SICE

  • D. Kim, H. Kim, W. Choi
  • 2003

A new design method for transient response control”, presente d at the SICE2003

  • D. Kim, H. Kim, W. Choi
  • Annual Conference,
  • 2003
1 Excerpt

Advanced pole placement methodology for no overshooting condition

  • D. Kim, H. Kim
  • Pro c.7 Korea-Russia International Symposium, KO…
  • 2003
3 Excerpts

Seborg, “Design of decentrali zed PI control systems based on Nyquist stabilit y analysis

  • D.E.D.Chen
  • Journal of Process Control, Vol.13,
  • 2003
1 Excerpt

Similar Papers