Design of an advanced TLD-based fixed nuclear accident dosimeter

@inproceedings{Casson1993DesignOA,
  title={Design of an advanced TLD-based fixed nuclear accident dosimeter},
  author={William H. Casson and G. T. Mei},
  year={1993}
}
A new system has been designed for use as a fixed nuclear accident dosimeter based upon the thermoluminescent dosimeter (TLD) system used for personnel dosimetry at US Department of Energy facilities managed by Martin Marietta Energy Systems, Inc. The system is made up of a small phantom consisting of two main parts measuring 20 x 20 x 5 cm and made from polymethylmethacrylate. A neutron-sensitive TLD card is placed in the center between the two pieces. Also, TLD cards in standard holders are… CONTINUE READING