DECAES - DEcomposition and Component Analysis of Exponential Signals.

@article{Doucette2020DECAESD,
  title={DECAES - DEcomposition and Component Analysis of Exponential Signals.},
  author={Jonathan Doucette and Christian Kames and Alexander Rauscher},
  journal={Zeitschrift fur medizinische Physik},
  year={2020}
}
Rapid parameter estimation for selective inversion recovery myelin imaging using an open-source Julia toolkit
TLDR
A fast, open-source toolkit for processing quantitative magnetization transfer derived from selective inversion recovery (SIR) acquisitions that allows parameter map estimation, including the myelin-sensitive macromolecular pool size ratio (PSR).
Rapid parameter estimation for selective inversion recovery myelin imaging using an open-source Julia toolkit
TLDR
A fast, open-source toolkit for processing quantitative magnetization transfer derived from selective inversion recovery (SIR) acquisitions that allows parameter map estimation, including the myelin-sensitive macromolecular pool size ratio (PSR).
A data‐driven T2 relaxation analysis approach for myelin water imaging: Spectrum analysis for multiple exponentials via experimental condition oriented simulation (SAME‐ECOS)
TLDR
A data‐driven and highly tailorable analysis method named spectrum analysis for multiple exponentials via experimental condition oriented simulation (SAME‐ECOS) was proposed.
Towards in vivo g-ratio mapping using MRI: Unifying myelin and diffusion imaging

References

SHOWING 1-10 OF 35 REFERENCES
Applications of stimulated echo correction to multicomponent T2 analysis
TLDR
Validation by means of both simulations and in vivo data shows excellent interscan reproducibility while vastly improving the accuracy of extracted T2 parameters in voxels where poor B1 homogeneity leads to refocusing pulse flip angles significantly less than 180°.
Myelin water imaging depends on white matter fiber orientation in the human brain
TLDR
It is found that the myelin water fraction (MWF) varied between 25% and 35% across different fiber orientations, which has important implications for future research and the interpretation of MWI results in previously published studies.
In vivo measurement of T2 distributions and water contents in normal human brain
Using a 32‐echo imaging pulse sequence, T2 relaxation decay curves were acquired from five white‐ and six gray‐matter brain structures outlined in 12 normal volunteers. The water contents of white
SENSE: Sensitivity encoding for fast MRI
TLDR
The problem of image reconstruction from sensitivity encoded data is formulated in a general fashion and solved for arbitrary coil configurations and k‐space sampling patterns and special attention is given to the currently most practical case, namely, sampling a common Cartesian grid with reduced density.
Non‐negative least squares computation for in vivo myelin mapping using simulated multi‐echo spin‐echo T2 decay data
TLDR
It is demonstrated that noise and imperfect refocusing flip angles yield systematic underestimations in MWF and intra−/extracellular water geometric mean T2 (gmT2).
Quantitative neuroimaging measures of myelin in the healthy brain and in multiple sclerosis
TLDR
Comparing the methods in terms of their statistical sensitivity to MS lesions in WM, MWF‐D demonstrated the best accuracy, and to aid future power analysis, the average and standard deviation volumes of the four techniques are provided.
Multi‐spin echo T2 relaxation imaging with compressed sensing (METRICS) for rapid myelin water imaging
TLDR
This work assessed the use of CS for in vivo human MWI, using a 3D multi spin‐echo sequence, and found that compressed sensing can vastly accelerate conventional MRI.
Heterogeneity of Multiple Sclerosis Lesions in Multislice Myelin Water Imaging
TLDR
MWI allows for quantitative assessment of NAWM and lesions in MS, which could be used as an additional sensitive imaging endpoint for larger MS studies and measures were in line with previous studies.
...
1
2
3
4
...