Current distribution measurement on the ITER-type NbTi bus bar III

@article{Zanino2005CurrentDM,
  title={Current distribution measurement on the ITER-type NbTi bus bar III},
  author={Roberto Zanino and Mar{\'i}a Eugenia Bagnasco and F. Bellina and Tullio Bonicelli and Antonio della Corte and Aldo Di Zenobio and W. H. Fietz and Alessandro Formisano and Richard F. Heller and Yu. A. Ilyin and V. Marchese and Raffaele Martone and Luigi Muzzi and Arend Nijhuis and Marek Pol{\'a}k and P. L. Ribani and Ettore Salpietro and L. C. Richard and S. Turtu' and Livio Verdini and G. R. Zahn},
  journal={IEEE Transactions on Applied Superconductivity},
  year={2005},
  volume={15},
  pages={1407-1410}
}
The Bus Bar III (BBIII), fabricated within the Toroidal Field Model Coil Task of the International Thermonuclear Experimental Reactor (ITER), was tested at the Forschungszentrum Karlsruhe, Germany, in the spring of 2004. The BBIII consists of an approximately 7 m long NbTi dual-channel conductor with a thick square stainless steel jacket, cooled by forced flow supercritical He. It was energized with currents up to 80 kA and operates in its self magnetic field (up to /spl sim/0.8 T). The BBIII… CONTINUE READING

Citations

Publications citing this paper.
SHOWING 1-9 OF 9 CITATIONS

Analysis and Simulation of the ITER-Type NbTi Bus BarIII With the THELMA Code

  • IEEE Transactions on Applied Superconductivity
  • 2006
VIEW 3 EXCERPTS
CITES BACKGROUND & METHODS
HIGHLY INFLUENCED

Uncertainty Analysis of Local and Integral Methods for Current Distribution Measurements

  • IEEE Transactions on Instrumentation and Measurement
  • 2013
VIEW 1 EXCERPT
CITES BACKGROUND

Study of Current Distribution in ITER TFMC NbTi Busbar III

  • IEEE Transactions on Applied Superconductivity
  • 2006
VIEW 1 EXCERPT
CITES METHODS

Preparation of the ITER poloidal field conductor insert (PFCI) test

  • IEEE Transactions on Applied Superconductivity
  • 2005
VIEW 1 EXCERPT
CITES BACKGROUND

References

Publications referenced by this paper.
SHOWING 1-6 OF 6 REFERENCES

Test of the 70 kA HTS Current Lead in the TOSKA Facility—Results of Test Phases I and II

R. Heller
  • Forschungszentrum Karlsruhe Internal Report, FE.5130.0061.0012/A, 2004.
  • 2004
VIEW 3 EXCERPTS

Data acquisition system for CDM on TFMC busbar, in EFDA Report Task TW1-TMC-CODES

S. Turtù, L. Verdini
  • Sub Task
  • 2003
VIEW 1 EXCERPT

Similar Papers

Loading similar papers…