Confirmation of Essure microinsert tubal coil placement with conventional and volume-contrast imaging three-dimensional ultrasound.

@article{Thiel2005ConfirmationOE,
  title={Confirmation of Essure microinsert tubal coil placement with conventional and volume-contrast imaging three-dimensional ultrasound.},
  author={John Thiel and Ian B. Suchet and Karine J Lortie},
  journal={Fertility and sterility},
  year={2005},
  volume={84 2},
  pages={504-8}
}
OBJECTIVE To determine the accuracy of ultrasound in the assessment of proximal fallopian tube positioning of the Essure microinsert coil 3 months after postprocedure. DESIGN Prospective cohort study (Canadian Task Force classification II-2). SETTING Reproductive-age women in a tertiary care hospital. PATIENT(S) Reproductive-age women presenting with a request for permanent contraception. INTERVENTION(S) Hysteroscopic sterilization with the Essure microinsert coil and conventional or… CONTINUE READING