Comparison of modeled and measured performance of a GSO crystal as gamma detector

@article{Parno2012ComparisonOM,
  title={Comparison of modeled and measured performance of a GSO crystal as gamma detector},
  author={Diana S. Parno and Megan Friend and V. H. Mamyan and F. Benmokhtar and Alexandre Camsonne and Gregg B. Franklin and Kent D. Paschke and B. Quinn},
  journal={Nuclear Instruments \& Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment},
  year={2012},
  volume={728},
  pages={92-96}
}
  • D. ParnoM. Friend B. Quinn
  • Published 15 November 2012
  • Physics
  • Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment

Figures and Tables from this paper

Precision Electron-Beam Polarimetry at 1 GeV Using Diamond Microstrip Detectors

Tests of the standard model of particle physics rely on measurements with highly polarized electron beams. A new instrument achieves the highest known precision for determining the beam polarization

Measurement of parity-violating asymmetry in electron-deuteron inelastic scattering

The parity-violating asymmetries between a longitudinally polarized electron beam and an unpolarized deuterium target have been measured recently. The measurement covered two kinematic points in the

Measurements of $d_{2}^{n}$ and $A_{1}^{n}$: Probing the neutron spin structure

We report on the results of the E06-014 experiment performed at Jefferson Lab in Hall A, where a precision measurement of the twist-3 matrix element d_2 of the neutron (d^n_2) was conducted. The

Hall A Annual Report 2014

Report of the experimental activities in Hall A at Thomas Jefferson National Accelerator Facility during 2013.

References

SHOWING 1-10 OF 14 REFERENCES

Scintillation properties of GSO

The timing properties of Gd/sub 2/SiO/sub 5/:Ce (GSO) single-crystal scintillators have previously been evaluated for positron emission tomography applications. The measured time resolution, however,

A Compton Polarimeter for CEBAF Hall A

Designed of the CEBAF Compton Polarimeter which will be used in the CEBAF Hall A is described. Some of the Hall A experimetns will use the 4 GeV polarized electron beam. Beam polarization and

Basic instrumentation for Hall A at Jefferson Lab

  • J. AlcornB. Anderson P. Zolnierczuk
  • Physics
    Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • 2004

From PET detectors to PET scanners

The properties of available and emerging radiation detector and read-out technologies are described and how they may affect PET scanner performance are discussed and the physical performance of the several commercial PET scanners is summarized.