Comparison of dye-dilution and plethysmographic blood flow measurements: an evaluation of the influence of invasive techniques on blood flow and on arterial and femoral venous substrate variables in man.
@article{Jorfeldt1990ComparisonOD, title={Comparison of dye-dilution and plethysmographic blood flow measurements: an evaluation of the influence of invasive techniques on blood flow and on arterial and femoral venous substrate variables in man.}, author={L. Jorfeldt and H. Rutberg}, journal={Clinical science}, year={1990}, volume={79 1}, pages={ 81-7 } }
1. In eight healthy volunteers we compared leg blood flow, as determined in a calf segment by strain-gauge plethysmography, with the flow measured by a constant-rate infusion of Indocyanine Green dye into the femoral artery. The representativeness of the calf segment was evaluated by complementary measurements with additional strain gauges attached around the proximal and distal crural and the distal thigh segments (n = 6). Furthermore, we investigated the influence of the catheterization… Expand
17 Citations
The direct effect of leg position on calf blood flow measured by venous occlusion plethysmography
- Medicine
- 2007
- 3
- PDF
Venous occlusion plethysmography vs. Doppler ultrasound in the assessment of leg blood flow kinetics during different intensities of calf exercise
- Medicine
- European Journal of Applied Physiology
- 2017
- 6
- PDF
Venous occlusion plethysmography versus Doppler ultrasound in the assessment of leg blood flow during calf exercise
- Medicine
- European Journal of Applied Physiology
- 2010
- 37
- Highly Influenced
Glucose-induced thermogenesis in splanchnic and leg tissues in man.
- Chemistry, Medicine
- Clinical science
- 1995
- 12
- PDF
Strain gauge plethysmography and Doppler ultrasound in the measurement of limb blood flow
- Medicine
- European journal of clinical investigation
- 1994
- 26
Performance of near-infrared spectroscopy in measuring local O(2) consumption and blood flow in skeletal muscle.
- Chemistry, Medicine
- Journal of applied physiology
- 2001
- 482
- PDF
Interaction between insulin sensitivity and muscle perfusion on glucose uptake in human skeletal muscle: evidence for capillary recruitment.
- Biology, Medicine
- Diabetes
- 2000
- 165
- PDF
References
SHOWING 1-10 OF 23 REFERENCES
Determination of human leg blood flow: a thermodilution technique based on femoral venous bolus injection.
- Medicine
- Clinical science and molecular medicine
- 1978
- 43
Measurement of Blood Flow in the Femoral Artery in Man at Rest and during Exercise by Local Thermodilution
- Medicine, Chemistry
- Circulation
- 1964
- 70
Investigation of arterial obstruction using a mercury-in-rubber strain gauge.
- Medicine
- American heart journal
- 1961
- 98
Effect of adrenaline on exchange of glucose in leg tissues and splanchnic area. A comparison with the metabolic response to surgical stress.
- Chemistry, Medicine
- Clinical physiology
- 1986
- 13
Measurement of skeletal muscle blood flow in humans: plethysmographic, bolus and continuous infusion technique.
- Medicine
- The American journal of cardiology
- 1988
- 12
Glucose metabolism during leg exercise in man.
- Chemistry, Medicine
- The Journal of clinical investigation
- 1971
- 574
The influence of ethanol on splanchnic and skeletal muscle metabolism in man.
- Chemistry, Medicine
- Metabolism: clinical and experimental
- 1978
- 128
Hemodynamics and leg muscle metabolism at rest and during exercise in young healthy men after prenalterol
- Chemistry, Medicine
- Clinical pharmacology and therapeutics
- 1983
- 5