Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography

@article{Kazemi2017ComparisonOA,
  title={Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schi{\o}tz Tonography},
  author={A. Kazemi and J. McLaren and S. Lin and C. Toris and V. Gulati and S. Moroi and A. Sit},
  journal={Investigative Ophthalmology & Visual Science},
  year={2017},
  volume={58},
  pages={204 - 210}
}
  • A. Kazemi, J. McLaren, +4 authors A. Sit
  • Published 2017
  • Materials Science, Medicine
  • Investigative Ophthalmology & Visual Science
Purpose It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. Methods Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting and supine positions with a pneumatonometer. With the subject in the supine position, IOP was recorded… Expand
8 Citations
Effect of Timolol on Aqueous Humor Outflow Facility in Healthy Human Eyes.
  • 2
The Effects of Netarsudil Ophthalmic Solution on Aqueous Humor Dynamics in a Randomized Study in Humans
  • 48
  • PDF
In vivo measurement of trabecular meshwork stiffness in a corticosteroid-induced ocular hypertensive mouse model
  • 26
  • PDF
Aqueous Humor Dynamics of the Brown-Norway Rat
  • 6
  • PDF
No flow through the vitreous humor: How strong is the evidence?
  • 4
  • Highly Influenced
  • PDF

References

SHOWING 1-10 OF 53 REFERENCES
Reproducibility of intraocular pressure and outflow facility measured by pneumatic tonography and Schiotz tonography.
  • 7
  • Highly Influential
Aqueous humor outflow facility by tonography does not change with body position.
  • 22
  • PDF
Comparative aqueous outflow facility measurements by pneumatonography and Schiotz tonography.
  • 18
  • Highly Influential
  • PDF
Pneumatonographic studies on normal and glaucomatus eyes.
  • 35
  • Highly Influential
Re-evaluation of the Schiotz tonometer calibration.
  • 20
  • PDF
Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of intraocular pressure.
  • 65
  • Highly Influential
  • PDF
Aqueous humor dynamics during the day and night in healthy mature volunteers.
  • 36
  • PDF
Tonographic method for measuring the facility and rate of aqueous flow in human eyes.
  • W. Grant
  • Medicine
  • Archives of ophthalmology
  • 1950
  • 130
...
1
2
3
4
5
...