Comparison Between Ultrafast and Standard SPECT in Patients with Coronary Artery Disease : A Pilot Study

@inproceedings{Gimelli2010ComparisonBU,
  title={Comparison Between Ultrafast and Standard SPECT in Patients with Coronary Artery Disease : A Pilot Study},
  author={Alessia Gimelli and Matteo Bottai and Assuero Giorgetti and Dario Genovesi and Annette Kusch and Andrea Ripoli and Paolo Marzullo},
  year={2010}
}
Background A novel technology has been developed for ultrafast (UF) singlephoton emission computed tomography (SPECT) myocardial perfusion imaging by employing a pin-hole collimation design and multiple cadmium zinc telluride crystal arrays. The purpose of this study was to compare myocardial perfusion imaging obtained by UF-SPECT with standard (S) SPECT in patients with known or suspected coronary artery disease. Methods and Results A total of 34 patients underwent single-day TcTetrofosmin… CONTINUE READING
4 Citations
19 References
Similar Papers

References

Publications referenced by this paper.
Showing 1-10 of 19 references

Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction

  • BA Herzog, RR Buechel, +8 authors PA. Kauffman
  • J Nucl Med
  • 2010
3 Excerpts

Clinical results of a novel wide beam reconstruction method shortening scan tine of Tc-99m cardiac SPECT perfusion studies

  • S Borges-Neto, RA Paganelli, +4 authors RE. Coleman
  • J Nucl Cardiol
  • 2007
1 Excerpt

Myoview Imaging optimization (MIO) multicenter study: feasibility and diagnostic accuracy of a new early and fast gated SPECT imaging protocol

  • A Giorgetti, M Rossi, +10 authors P. Marzullo
  • J Nucl Med
  • 2007
1 Excerpt

Similar Papers