Comparative structural neck responses of the THOR-NT, Hybrid III, and human in combined tension-bending and pure bending.

@article{Dibb2006ComparativeSN,
  title={Comparative structural neck responses of the THOR-NT, Hybrid III, and human in combined tension-bending and pure bending.},
  author={Alan Thomas Dibb and Roger W. Nightingale and Valeta Carol Chancey and Lucy E Fronheiser and Laura L. Tran and Danielle Ottaviano and Barry S Meyers},
  journal={Stapp car crash journal},
  year={2006},
  volume={50},
  pages={
          567-81
        }
}
This study evaluated the biofidelity of both the Hybrid III and the THOR-NT anthropomorphic test device (ATD) necks in quasistatic tension-bending and pure-bending by comparing the responses of both the ATDs with results from validated computational models of the living human neck. This model was developed using post-mortem human surrogate (PMHS) osteoligamentous response corridors with effective musculature added (Chancey, 2005). Each ATD was tested using a variety of end-conditions to create… CONTINUE READING