• Corpus ID: 20359514

Comments on the arterial spin labelling quantification recommended by the ISMRM perfusion study group and the European consortium for ASL in dementia

@article{Kerskens2017CommentsOT,
  title={Comments on the arterial spin labelling quantification recommended by the ISMRM perfusion study group and the European consortium for ASL in dementia},
  author={Christian Matthias Kerskens},
  journal={arXiv: Other Quantitative Biology},
  year={2017}
}
  • C. Kerskens
  • Published 11 March 2017
  • Medicine
  • arXiv: Other Quantitative Biology
A petition for more careful considerations towards the usage of a quantification approach for ASL which has been recommended by the ISMRM perfusion study group and the European consortium for ASL in dementia. 
1 Citations

Figures from this paper

References

SHOWING 1-3 OF 3 REFERENCES
Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia
TLDR
This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications and describes the major considerations and trade‐offs in implementing an ASL protocol and provides specific recommendations for a standard approach.
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
TLDR
A general kinetic model for the ASL signal is described that can be used to assess systematic errors in arterial spin labeling techniques and provided a good description of pulsed ASL data during a simple sensorimotor activation task.