Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.
@article{Yates2008CollarlessPT,
title={Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.},
author={Piers J Yates and Ben J Burston and Elise Whitley and Gordon C. Bannister},
journal={The Journal of bone and joint surgery. British volume},
year={2008},
volume={90 1},
pages={
16-22
}
}We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip…
49 Citations
Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up.
- MedicineThe Journal of bone and joint surgery. British volume
- 2012
The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation, and its results are consistent with other polished tapered stem designs.
Hip Arthroplasty Using Collarless Polished Tapered Stem -Minimum 2 Years Follow-up Results-
- Medicine
- 2012
A long-term follow-up study will be needed to evaluate the more precise clinical and radiographic outcomes of THA and BHA with a cemented CPT femoral stem at the mid-termFollow-up.
A Cannulated Tri-Tapered Femoral Stem for Total Hip Arthroplasty: Clinical and Radiological Results at Ten Years.
- MedicineThe Journal of arthroplasty
- 2015
Minimum ten-year outcome of a triple-tapered femoral stem implanted with line-to-line cementing technique
- MedicineBMC Musculoskeletal Disorders
- 2021
Line-to-line cementing technique with use of a triple-tapered polished femoral stem was effective to achieve good cementation quality and centralization of the stem.
Cement in cement revision of the femoral component using a collarless triple taper: a midterm clinical and radiographic assessment.
- MedicineThe Journal of arthroplasty
- 2014
Long-Term Survival of the Cemented Exeter Universal Stem in Patients 50 Years and Younger: An Update on 130 Hips.
- MedicineThe Journal of arthroplasty
- 2019
Advantages in Using Cemented Polished Tapered Stems When Performing Total Hip Arthroplasty in Very Young Patients.
- MedicineThe Journal of arthroplasty
- 2017
Results of the cemented Exeter femoral component in patients under the age of 40: AN UPDATE AT TEN TO 20 YEARS' FOLLOW‐UP
- MedicineThe bone & joint journal
- 2017
The Exeter femoral component continues to function satisfactorily in young patients for up to 17 years after surgery.
Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up
- MedicineInternational Orthopaedics
- 2013
Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR, and good walking performance in a real-life environment is confirmed.
Cemented polished tapered stems in patients less than 50 years of age: a minimum 10-year follow-up.
- MedicineThe Journal of arthroplasty
- 2010
References
SHOWING 1-10 OF 50 REFERENCES
Primary exeter total hip arthroplasty in patients with small femurs: a minimal of 10 years follow-up.
- MedicineThe Journal of arthroplasty
- 2005
Sixteen-year follow-up of the cemented spectron femoral stem for hip arthroplasty.
- MedicineThe Journal of arthroplasty
- 2003
The Exeter Universal stem: a minimum ten-year review from an independent centre.
- MedicineThe Journal of bone and joint surgery. British volume
- 2006
The findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.
Ten-year survival of the MS-30 matt-surfaced cemented stem.
- MedicineThe Journal of bone and joint surgery. British volume
- 2005
The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence.
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.
- MedicineThe Journal of bone and joint surgery. American volume
- 1999
The hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation.
Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.
- MedicineThe Journal of bone and joint surgery. British volume
- 1992
To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or…
The ScanHip ® total hip arthroplasty: Radiographic assessment of 72 hips after 10 years
- MedicineActa orthopaedica Scandinavica
- 2002
Preliminary results suggest that precise serial long-term radiographic follow-up is the only satisfactory method for detecting aseptic loosening of total hip arthroplasty.
Loosening and bone resorption in exeter hip arthroplasties. Review at a minimum of five years.
- MedicineThe Journal of bone and joint surgery. British volume
- 1993
The late complication rate with the matt-surfaced Exeter femoral stem is unacceptably high and half the patients with loosening or localised bone resorption had mild pain or no pain at all.
Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience.
- MedicineThe Journal of arthroplasty
- 2001
The first 500 primary hip arthroplasties at a mean follow-up of 3 years, 5 months are described; there have been no revisions for aseptic stem loosening, and no stem is considered to be at risk for loosening.
Radiographic assessment of 72 hips after 10 years
- Medicine
- 2002
We analyzed the radiographic and clini- cal outcome of the ScanHip total hip arthroplasty in 70 patients after 10 years. The Swedish National Hip Reg- ister, in which the end-point of the survival…





