Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

@article{Yates2008CollarlessPT,
  title={Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.},
  author={Piers J Yates and Ben J Burston and Elise Whitley and Gordon C. Bannister},
  journal={The Journal of bone and joint surgery. British volume},
  year={2008},
  volume={90 1},
  pages={
          16-22
        }
}
We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cementing with a gun and proximal pressurisation. Clinical outcome was assessed using the Harris Hip… 
Clinical and radiological results of the collarless polished tapered stem at 15 years follow-up.
TLDR
The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation, and its results are consistent with other polished tapered stem designs.
Hip Arthroplasty Using Collarless Polished Tapered Stem -Minimum 2 Years Follow-up Results-
TLDR
A long-term follow-up study will be needed to evaluate the more precise clinical and radiographic outcomes of THA and BHA with a cemented CPT femoral stem at the mid-termFollow-up.
Minimum ten-year outcome of a triple-tapered femoral stem implanted with line-to-line cementing technique
TLDR
Line-to-line cementing technique with use of a triple-tapered polished femoral stem was effective to achieve good cementation quality and centralization of the stem.
Results of the cemented Exeter femoral component in patients under the age of 40: AN UPDATE AT TEN TO 20 YEARS' FOLLOW‐UP
TLDR
The Exeter femoral component continues to function satisfactorily in young patients for up to 17 years after surgery.
Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up
TLDR
Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR, and good walking performance in a real-life environment is confirmed.
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 50 REFERENCES
The Exeter Universal stem: a minimum ten-year review from an independent centre.
TLDR
The findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.
Ten-year survival of the MS-30 matt-surfaced cemented stem.
TLDR
The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence.
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.
TLDR
The hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation.
Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.
To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or
The ScanHip ® total hip arthroplasty: Radiographic assessment of 72 hips after 10 years
TLDR
Preliminary results suggest that precise serial long-term radiographic follow-up is the only satisfactory method for detecting aseptic loosening of total hip arthroplasty.
Loosening and bone resorption in exeter hip arthroplasties. Review at a minimum of five years.
TLDR
The late complication rate with the matt-surfaced Exeter femoral stem is unacceptably high and half the patients with loosening or localised bone resorption had mild pain or no pain at all.
Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience.
TLDR
The first 500 primary hip arthroplasties at a mean follow-up of 3 years, 5 months are described; there have been no revisions for aseptic stem loosening, and no stem is considered to be at risk for loosening.
Radiographic assessment of 72 hips after 10 years
We analyzed the radiographic and clini- cal outcome of the ScanHip total hip arthroplasty in 70 patients after 10 years. The Swedish National Hip Reg- ister, in which the end-point of the survival
...
1
2
3
4
5
...