Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique.

@article{Bae2009ClosedwedgeHT,
  title={Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique.},
  author={D. Bae and S. J. Song and K. Yoon},
  journal={The Journal of bone and joint surgery. British volume},
  year={2009},
  volume={91 9},
  pages={
          1164-71
        }
}
We assessed the reliability, accuracy and variability of closed-wedge high tibial osteotomy (HTO) using computer-assisted surgery compared to the conventional technique. A total of 50 closed-wedge HTO procedures were performed using the navigation system, and compared with 50 HTOs that had been performed with the conventional technique. In the navigation group, the mean mechanical axis prior to osteotomy was varus 8.2 degrees, and the mean mechanical axis following fixation was valgus 3.6… Expand
68 Citations
Computer-assisted navigation decreases the change in the tibial posterior slope angle after closed-wedge high tibial osteotomy
Change in limb length after high tibial osteotomy using computer-assisted surgery: a comparative study of closed- and open-wedge osteotomies
Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques
...
1
2
3
4
5
...

References

SHOWING 1-10 OF 41 REFERENCES
Computer aided high tibial open wedge osteotomy.
The effect of closed wedge high tibial osteotomy on tibial slope: a radiographic study
Opening Wedge High Tibial Osteotomy for Symptomatic Hyperextension-Varus Thrust
Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy.
  • C. Marti, E. Gautier, S. Wachtl, R. Jakob
  • Medicine
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
  • 2004
...
1
2
3
4
5
...