Case Studies to Demonstrate the Range of Applications of the Southampton Hand Assessment Procedure
@article{Kyberd2009CaseST, title={Case Studies to Demonstrate the Range of Applications of the Southampton Hand Assessment Procedure}, author={P. Kyberd and A. Murgia and M. Gasson and Tristan Tjerks and C. Metcalf and P. Chappell and K. Warwick and S. Lawson and T. Barnhill}, journal={The British Journal of Occupational Therapy}, year={2009}, volume={72}, pages={212 - 218} }
The Southampton Hand Assessment Procedure (SHAP) was devised to assess quantitatively the functional range of injured and healthy adult hands. [...] Key Result The cases show that the SHAP is capable of monitoring progress and recovery, identifying functional abilities in prosthetic hands and comparing the capabilities of different groups of injuries.Expand
Figures, Tables, and Topics from this paper
72 Citations
Preliminary study of the Southampton Hand Assessment Procedure for Children and its reliability
- Medicine
- BMC Musculoskeletal Disorders
- 2014
- 7
- PDF
Functional and Psychosocial Outcomes of Hand Transplantation Compared with Prosthetic Fitting in Below-Elbow Amputees: A Multicenter Cohort Study
- Medicine
- PloS one
- 2016
- 34
- PDF
Biomechanical analysis of users of multi-articulating externally powered prostheses with and without their device
- Medicine
- Prosthetics and orthotics international
- 2019
Prosthetic reconstruction to restore function in transcarpal amputees.
- Medicine
- Journal of plastic, reconstructive & aesthetic surgery : JPRAS
- 2016
- 9
Comparative clinical evaluation of the Yale Multigrasp Hand
- Engineering, Computer Science
- 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob)
- 2016
- 9
- PDF
Functional assessment of the vanderbilt multigrasp myoelectric hand: A continuing case study
- Engineering, Computer Science
- 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- 2014
- 13
Functional Outcome Scores With Standard Myoelectric Prostheses in Below-Elbow Amputees
- Medicine
- American journal of physical medicine & rehabilitation
- 2019
- 2
- PDF
Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees
- Medicine
- Prosthetics and orthotics international
- 2018
- 14
References
SHOWING 1-10 OF 34 REFERENCES
Sollerman hand function test. A standardised method and its use in tetraplegic patients.
- Medicine
- Scandinavian journal of plastic and reconstructive surgery and hand surgery
- 1995
- 339
- PDF
Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity.
- Psychology, Medicine
- Archives of physical medicine and rehabilitation
- 2002
- 284
- PDF
External fixators for wrist fractures: a biomechanical and clinical study.
- Medicine
- The Journal of hand surgery
- 1985
- 76
Evaluation of impairment of the upper extremity.
- Medicine
- Clinical orthopaedics and related research
- 1987
- 36
The prehensile movements of the human hand.
- Medicine
- The Journal of bone and joint surgery. British volume
- 1956
- 1,157
- PDF
Factors affecting functional outcome of displaced intra-articular distal radius fractures.
- Medicine
- The Journal of hand surgery
- 1994
- 513
Fractures of the Distal End of the Radius in Young Adults: A 30-Year Follow-Up
- Medicine
- Journal of hand surgery
- 1993
- 167
The application of implant technology for cybernetic systems.
- Computer Science, Medicine
- Archives of neurology
- 2003
- 201
- PDF