Cage-rotor induction motor inter-turn short circuit fault detection with and without saturation effect by MEC model.

@article{Naderi2016CagerotorIM,
  title={Cage-rotor induction motor inter-turn short circuit fault detection with and without saturation effect by MEC model.},
  author={Peyman Naderi},
  journal={ISA transactions},
  year={2016},
  volume={64},
  pages={
          216-230
        }
}
The inter-turn short fault for the Cage-Rotor-Induction-Machine (CRIM) is studied in this paper and its local saturation is taken into account. However, in order to observe the exact behavior of machine, the Magnetic-Equivalent-Circuit (MEC) and nonlinear B-H curve are proposed to provide an insight into the machine model and saturation effect respectively. The electrical machines are generally operated near to their saturation zone due to some design necessities. Hence, when the machine is… CONTINUE READING
BETA

Citations

Publications citing this paper.
SHOWING 1-9 OF 9 CITATIONS

References

Publications referenced by this paper.
SHOWING 1-10 OF 36 REFERENCES

Pole arc skewing analysis of synchronous reluctance machine using discrete method combined with winding function approach

  • P Naderi, A. Shiri
  • Appl Comput Electromagn Soc
  • 2015

An improved magnetic equivalent circuit method for evaluation of different inductances of a squirrel - cage induction motor in healthy and faulty conditions

  • J Faiz, M Ghasemi, M Ebrahimi
  • Electromagnetic
  • 2014

An improved magnetic equivalent circuit method for evaluation of different inductances of a squirrel-cage induction motor in healthy and faulty conditions. Electromagnetic 2014;34:363–79

  • J Faiz, M Ghasemi, M. Ebrahimi
  • 2014
1 Excerpt