CONSIDERATIONS ON POWER TRANSFORMER CONDITION- BASED MAINTENANCE

@inproceedings{Sokolov2007CONSIDERATIONSOP,
  title={CONSIDERATIONS ON POWER TRANSFORMER CONDITION- BASED MAINTENANCE},
  author={Victor V. Sokolov},
  year={2007}
}
The paper discusses concepts of the transformer condition based monitoring focused on maintaining the equipment functional serviceability. Typical scenarios of transformer failures are presented based on the analysis of large power transformer failures in the recent years. Using the experience with in-field assessment of the conditions of large power transformers the paper attempts to answer some questions: How to move to a condition-based methodology? What are the really effective diagnostic… 

Figures and Tables from this paper

TRANSFORMER FLUID : A POWERFUL TOOL FOR THE LIFE MANAGEMENT OF AN AGEING TRANSFORMER POPULATION

It has been estimated that transformer fluids contain about 70% of the diagnostic information available for transformers. The challenge is to access and use this information effectively.

On-load tap changer diagnosis with dynamic resistance measurements

A modern tendency is to perform condition-based rather than time-based maintenance on power transformers. This requires the use of diagnostic measurements to know the condition of the tap changer and

Sub-system based reliability assessment for distribution transformer

Implementation of Smart Grid into the power system has made our grid more robust and reliable. Due to integration of two-way, real time communication it is possible to monitor equipment through

On-load Tap Changer Diagnosis on High-Voltage Power Transformers using Dynamic Resistance Measurements

High-voltage transformers have tap changers to regulate the voltage in the high-voltage network when the load changes. Those tap changers are subject to different degradation mechanisms and need

Diagnosis of degradation effects of on-load tap changer in power transformers

By performing diagnostics on on-load tap changers by means of dynamic resistance measurements a condition diagnosis of high-speed resistor-type tap changers can result in pre-failure detection of

Development and application of the intensive care units on transformers

TLDR
The intensive care unit on the transformer enables the ultrasonic, ultra-high-frequency and high-frequency current detection, and provides useful references for the maintenance strategy of substation.

EXPERIENCE WITH DETECTION AND IDENTIFICATION OF WINDING BUCKLING IN POWER TRANSFORMERS

The paper summarizes experience with identification of buckling of inner windings using leakage reactance matrix of changes. The diagnostic threshold values are suggested. The case studies of units

Identifying worst performing components in a distribution system using Weibull distribution

  • V. AravinthanW. Jewell
  • Engineering
    2010 IEEE 11th International Conference on Probabilistic Methods Applied to Power Systems
  • 2010
A condition based component maintenance scheme for distribution transformers is proposed. The component is analyzed based on its failure modes. Failure modes are defined based on the manufacturer's

Load Management Design Methods by Displacement and Affectation in Ageing Level of Distribution Transformers

TLDR
This research analyses distribution transformers and a useful life extension impact through two proposals concerning a change in residential customers consumption behaviour: load management by displacement, or a reduction in consumption in 26,386 subscribers from the utility CNEL Guayas-Los Rios in Puntilla-Samborondón counties.

The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing

The healthy state of insulation in oil-impregnated bushings is traditionally evaluated by tanδ and capacitance at power frequency and mostly at 10 kV in the test standard. However, there has

References

SHOWING 1-10 OF 24 REFERENCES

Effective methods of assessment of insulation system conditions in power transformers: a view based on practical experience

  • V. SokolovZ. BerlerV. Rashkes
  • Physics
    Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035)
  • 1999
Condition-based monitoring of power transformer insulation should center on the prediction of a substantial drop in the dielectric safety margin under the impact of moisture, oil by-products,

EVALUATION OF POWER TRANSFORMER INSULATION THROUGH MEASUREMENT OF DIELECTRIC CHARACTERISTICS

This paper summarizes our experience with the evaluation of the insulation condition and the identification of defects in spaces of the main insulation of power transformers. Specifically, this

EVALUATION AND IDENTIFICATION OF TYPICAL DEFECTS AND FAILURE MODES IN 110-750 kV BUSHINGS

This paper discusses the typical defects and failure modes associated with high-voltage transformer bushings based upon experience gained from a large population of bushings as well as other studies

A new method of partial discharge measurements

Partial discharge (PD) measurements on high voltage equipment has become one of the main tools in predictive maintenance programs as a very valuable source of information in everyday equipment state

Biography

TLDR
The author is involved with several projects related to big data analytics, multimodal data fusion, cyber-physical security, and anomaly detection, and leads the Data and Signal Analysis (DASA) research group.

“A and B”:

Direct fabrication of large micropatterned single crystals. p1205 21 Feb 2003. (news): Academy plucks best biophysicists from a sea of mediocrity. p994 14 Feb 2003.

A and V

TRANSFORMER LIFE MANAGEMENT CONSIDERATIONS

On-Line Vibro-Acoustic Alternative to the Frequency Response Analysis and On-Line Partial Discharge Measurements on Large Power Transformers

  • Proceedings of the Techcon '99 Annual Conference, TJ/H2b
  • 1999

Life Management of Transformers Activity- Overview

  • CIGRE SC12 Colloquium,
  • 1997