The CLIC (Compact Linear Collider) high-gradient RF structure testing program has been carried out in order to gain insight into the physical processes involved in RF breakdown, determine the mechanisms that limit gradient and produce damage so that technical concepts can be developed which allow higher accelerating gradients. Two main paths towards higher gradients have emerged from this program, and the performances of two new structures which incorporate them are presented. 