In this work the design, simulation and measurement results of high voltage level shifters (LS) is presented. A modification is introduced to the standard LS, and a design criterion was developed, for the level shifter to work in a very wide range of operation from 0 to 18V. Also, safety issues where addressed when the level shifters are used to deliver… (More)