Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.

@article{Yang2013BiomechanicalCO,
  title={Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.},
  author={Shan-Wei Yang and Shyh Ming Kuo and Shwu Jen Chang and T. Su and Hsiang-Ho Chen and Jenn-Huei Renn and Ting-Sheng Lin},
  journal={Orthopedics},
  year={2013},
  volume={36 10},
  pages={
          e1316-21
        }
}
The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. [] Key Method Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture.

Figures from this paper

Biomechanical Analysis of Latarjet Screw Fixation: Comparison of Screw Types and Fixation Methods.
  • Jason J Shin, J. Hamamoto, +9 authors N. Verma
  • Medicine, Biology
    Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
  • 2017
Effect of different inner core diameters on structural strength of cannulated pedicle screws under various lumbar spine movements
TLDR
Cannulated screws could provide enough stability for the vertebral body fusion comparing to solid screws, if the diameter of cannulated core is suggested not to exceed 2.0 mm.
Latarjet Fixation
TLDR
There was no statistically significant difference in energy or cycles to failure when comparing the stainless steel cortical screws versus partially threaded cannulated cancellous screws in the Latarjet procedure.

References

SHOWING 1-10 OF 17 REFERENCES
Factors affecting the pullout strength of cancellous bone screws.
TLDR
To determine how screw thread geometry, tapping, and cannulation affect the holding power of screws in cancellous bone and whether current designs achieve maximum purchase strength, 12 types of commercially available cannulated and noncannulated cancellousBone screws were tested for pullout strength in rigid unicellular polyurethane foams.
Pullout Strengths of Cannulated and Noncannulated Cancellous Bone Screws
TLDR
The pullout strengths of large diameter cannulated and noncannulated cancellous screws were tested in a synthetic polyurethane foam and thread surface area was found to be a reasonable predictor of holding power.
Extraction Strength of Cannulated Cancellous Bone Screws
TLDR
It was showed that the extraction strength of cancellous bone screws is not altered by the changes in thread-to-core ratio accommodating cannulation, and the maximum force values attained were determined as the screws' holding strengths.
An in vitro biomechanical comparison of the insertion variables and pullout mechanical properties of ao 6.5-mm standard cancellous and 7.3-mm self-tapping, cannulated bone screws in foal femoral bone.
TLDR
It is unlikely that increasing the screw diameter beyond 6.5 mm will provide increased holding power in foal femoral bone, and the 7.3-mm cannulated screw should be considered for foal Femoral fracture repair when greater accuracy is needed, or when bone threads for the 6.
Mechanical Properties of Small Fragment Screws
TLDR
Comparison of the mechanical properties of several commonly used small fragment screws showed that cannulated stainless steel cortical, titanium cortical screws, stainless steel cancellous screws, and polylactic acid screws had the least bending strength and other metal screws had lower yield strength and maximal load at failure than did the standard Stainless steel cortical screws.
...