• Corpus ID: 23243185

Biologic effects of implant debris.

@article{Hallab2009BiologicEO,
  title={Biologic effects of implant debris.},
  author={Nadim James Hallab and Joshua J. Jacobs},
  journal={Bulletin of the NYU hospital for joint diseases},
  year={2009},
  volume={67 2},
  pages={
          182-8
        }
}
  • N. HallabJ. Jacobs
  • Published 2009
  • Biology, Materials Science
  • Bulletin of the NYU hospital for joint diseases
Biologic response to orthopedic implants debris is central to clinical performance. Eventual implant loosening due to aseptic osteolysis has been attributed to local inflammatory responses to wear and corrosion products that are produced by articulating implant interfaces. The response to implant debris is dominated by local immune activation, e.g. macrophages. Immune reactivity has been shown to depend on the number of particles produced or the dose (i.e., the concentration of phagocytosable… 

Figures and Tables from this paper

The Inflammatory Effects of Breast Implant Particulate Shedding: Comparison With Orthopedic Implants

Differentiating normal innate immune reactivity to particles from anaplastic large cell lymphoma reactions from delayed type hypersensitivity reactions to BI-associated implant debris remains unclear but vital to patients and surgeons.

Biological response to prosthetic debris.

Comprehensive understanding of the intricate process of osteolysis is of utmost importance for future development of therapeutic modalities that may delay or prevent the disease progression.

Current research in the pathogenesis of aseptic implant loosening associated with particulate wear debris.

This review summarizes current concepts of how wear debris causes osteolysis, and describes the interaction and effects of wear debris on functions of primary cell types involved in osteolytic disease.

The basic science of periprosthetic osteolysis.

Research continues with the hope that viable strategies for preventing and treating particle-induced osteolysis will be introduced in the future, thus mitigating the need for revision surgery.

The potential role of human osteoblasts for periprosthetic osteolysis following exposure to wear particles.

Evaluating to what extent human primary osteoblasts exposed to wear particles are involved in the osteolysis revealed distinct effects on the cytokine release of human osteoblast towards particulate debris, which revealed increased levels of interleukine (IL)-6 and IL-8 after treatment with metallic wear particles.

The distribution and pro-inflammatory impact of titanium debris accumulation in the peri-implant environment

The findings strongly indicated that neutrophil responses can be modified by Ti species and further work is needed to identify the role that ‘free Ti’ has on implant outcomes.

Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages.

CoCrMo-alloy particles were by far the most toxic and decreased viability and proliferation of human osteoblasts, fibroblasts, and macrophages by >50% at a dose of only 50 particles per cell and Zr-based particles induced less toxicity and inflammatory responses.

Involvement of extracellular Hsp72 in wear particle-mediated osteolysis.

The pathobiology and pathology of aseptic implant failure

Physical and chemical characteristics of implant wear influence the nature of the response in periprosthetic tissues and account for the development of particular complications that lead to implant failure, such as osteolysis which leads to aseptic loosening, and soft-tissue necrosis/inflammation, which can result in pseudotumour formation.
...

References

SHOWING 1-10 OF 40 REFERENCES

The biology of aseptic osteolysis.

The immune system and skeletal homeostasis may be linked in the process of osteoclastogenesis and osteolysis and the fundamental role of the RANKL-RANK-NF-kappaB pathway not only in osteOClastogenesis but also in the development and function the immune system.

The effects of titanium and polymethylmethacrylate particles on osteoblast phenotypic stability.

The data show that titanium but not PMMA particles shifts bone cell metabolism to preferentially produce fibrous tissue rather than bone, which reduces the need for total joint arthroplasty.

Wear Debris in Total Joint Replacements

The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis, to develop preventive measures that will minimize the clinical impact of this phenomenon.

The Effects of Particulate Wear Debris, Cytokines, and Growth Factors on the Functions of MG-63 Osteoblasts

Osteoblast-derived interleukin-6 may induce osteoclast differentiation and/or activation, but the resorbed bone cannot be replaced by new bone because of diminished osteoblast function (reduced type-I collagen synthesis).

Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.

The data suggest that both shape and texture influence the severity of specific inflammatory responses and that rough debris surface texture exerts a marked effect on adverse tissue responses when combined with particles that have a sharp, elongated shape.

Gene expression analysis of osteoblastic cells contacted by orthopedic implant particles.

Results from this study suggest that the peri-implant osteolysis after a total joint replacement can be due in part to a decrease of bone formation and not solely to an overstimulation of bone resorption as is generally proposed.

Metal sensitivity in patients with orthopaedic implants.

Until the roles of delayed hypersensitivity and humoral immune responses to metallic orthopaedic implants are more clearly defined, the risk to patients may be considered minimal.

Human monocyte response to particulate biomaterials generated in vivo and in vitro

TiAlV particles appeared to be the most competent to elicit the synthesis and release of inflammatory mediators in human monocytes, albeit at a lower level, whereas the particles of polyethylene retrieved from interfacial membranes were less stimulatory in these short‐term in vitro experiments.

Reactions of the articular capsule to wear products of artificial joint prostheses.

Examination of a great number of tissue samples taken from the newly formed capsules surrounding artificial joints reveals small particles of prosthetic material, which initiate a foreign-body reaction and result in the formation of granulation tissue, including macrophages and foreign- body giant cells.