Bioenergetic comparison of a new energy-storing foot and SACH foot in traumatic below-knee vascular amputations.

@article{Casillas1995BioenergeticCO,
  title={Bioenergetic comparison of a new energy-storing foot and SACH foot in traumatic below-knee vascular amputations.},
  author={Jean-Marie Casillas and V{\'e}ronique Dulieu and Mabelle Cohen and I F Marcer and James Didier},
  journal={Archives of physical medicine and rehabilitation},
  year={1995},
  volume={76 1},
  pages={39-44}
}
In this study, the metabolic performances of a new energy-storing foot (Proteor) and of the solid-ankle cushion heel (SACH) are compared. Twelve patients with traumatic below-knee amputations (mean age: 50.0 +/- 19.9 years) and 12 patients with vascular below-knee amputations (mean age: 73 +/- 7 years) were studied. Oxygen uptake (VO2) was measured in all the subjects on a walkway at a self-selected velocity; only the subjects with traumatic amputation were tested on a level treadmill… CONTINUE READING