Corpus ID: 42927541

Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit

@inproceedings{Noureldeen2012BehaviorOD,
  title={Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit},
  author={Omar Noureldeen},
  year={2012}
}
Doubly Fed Induction Generators DFIG are nowadays widely used in variable speed wind power plants. The dynamic interaction between variable speed DFIG wind turbines and the power system which is subjected to disturbances, such as short circuit faults, is an important issue. The ability of the wind power plant to stay connected to the grid during disturbances is important to avoid a cascading effect due to lack of power. This paper investigates the impact of fault ride through on the stability… Expand

Figures and Tables from this paper

Improvement FRT Capability of DFIG Wind Energy based on Three Level Converter
This paper investigates the dynamic behavior of wind farm based on DFIG wind turbines during three phase to ground fault at wind farm terminals using different types of protection. Also, it schemesExpand
EVALUATION & PERFORMANCE ANALYSIS OF DFIG WIND TURBINE WITH CROWBAR PROTECTION UNDER SHORT CIRCUIT & VOLTAGE DIP CONDITION
Wind energy is the fastest and most promising energy source. Due to many advantages such as the improved power quality, high energy efficiency and controllability, etc. the variable speed windExpand
Comparison among different crowbar protection techniques for modern wind farms under short circuit occurrence
  • M. Rihan
  • Computer Science
  • 2017 Nineteenth International Middle East Power Systems Conference (MEPCON)
  • 2017
TLDR
A comprehensive comparison between the effectiveness of different crowbar techniques on protecting the DFIG-based wind farms is presented in this work, this comparison has been carried out by simulation on a typical 9 MW DFIG -based wind farm using the MATLAB simpowersystems. Expand
Transient Stability Analysis and Fault Ride-Through Augmentation of a Doubly Fed Induction Generator in a 9- Bus Power System
TLDR
The effects of integration of wind farms in a WSCC 3-generator 9-bus system is examined to investigate the transient stability and a study has been carried out to compare the Fault Ride-Through behavior of DFIG by employing a Capacitive- Resistive Bridge Fault Current Limiter via simulation. Expand
Fault Ride Through Capability Enhancement of Doubly Fed Wind Generator Using Hybrid Protection Circuits
  • Bunan Tipo, J. Li, Boyu Qin
  • Engineering
  • 2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP)
  • 2019
This paper presents a new FRT control strategy to improve the dynamic response of doubly fed induction generator based wind turbine (DFIG-WT) during grid fault. The proposed control scheme is basedExpand
Assessment of influence of grid disturbances on wind turbine DFIG converters
The aim of this paper is to study the behaviour of wind turbine generator during an external grid disturbance. The wind power generation system stability depends on many parameters such as faultExpand
Application of Crowbar and STATCOM for Actual Field Condition
Wind power generation is increasing rapidly in India and wind integration with the grid is considered as a promising source of energy, Double Fed Induction Generator (DFIG) being the most commonlyExpand
Modeling and Fault Analysis of Doubly Fed Induction Generators for Gansu Wind Farm Application
Wind power is developing rapidly as a means of handling the world's energy shortage and associated environmental problems. The Gansu provincial wind energy resources have around 237-GW wind powerExpand
An efficient ANFIS crowbar protection for DFIG wind turbines during faults
  • Omar Noureldeen, I. Hamdan
  • Computer Science
  • 2017 Nineteenth International Middle East Power Systems Conference (MEPCON)
  • 2017
TLDR
This paper presents the design of an Adaptive Neuro-Fuzzy Inference System (ANFIS) crowbar protection strategy for Doubly Fed Induction generator wind turbines during grid faults to protect the generator components during faults especially the DC-link capacitor and power electronic converters. Expand
Comparative assessment of double-fed induction generator and full converter generator wind turbines on short circuits in distribution systems
With the ever-increasing exploitation of wind turbines for electric power generation, their effects on short circuits are among the important issues in this respect. This issue is of great importanceExpand
...
1
2
...

References

SHOWING 1-10 OF 13 REFERENCES
Fault ride-through capability of DFIG wind turbines
This paper concentrates on the fault ride-through capability of doubly fed induction generator (DFIG) wind turbines. The main attention in the paper is, therefore, drawn to the control of the DFIGExpand
Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators
This paper deals with the low voltage ride-through (LVRT) control of wind turbines with doubly fed induction generators (DFIGs) under symmetrical voltage dips. The investigation first develops aExpand
Fault ride through and voltage regulation for grid connected wind turbine
High penetration of wind generation challenges wind turbine operators to supply reliable power and extract optimum power from the wind. Hence, the fault ride through (FRT) capability of wind turbineExpand
Dynamic voltage restorer to allow LVRT for a DFIG wind turbine
The application of a Dynamic Voltage Restorer connected to a wind turbine driven doubly fed induction generator (DFIG) is investigated. The setup allows the wind turbine system an uninterruptibleExpand
Dynamic Characteristic Analysis of Doubly-fed Induction Generator Low Voltage Ride-through
Abstract For studying the impacts of wind turbines integrated into grid, the relation between the protection of doubly-fed induction generator (DFIG) during low voltage fault and the dynamicExpand
Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips
The use of doubly fed induction generators (DFIGs) in large wind turbines has become quite common over the last few years. These machines provide variable speed and are driven with a power converterExpand
Investigation of transient models and performances for a doubly fed wind turbine under a grid fault
In order to investigate the impacts of the integration of wind farms into utilities network, it is necessary to analyze the transient performances of wind turbine generation systems (WTGS) with theExpand
Specification of rotor side voltage source inverter of a doubly-fed induction generator for achieving ride-through capability
The ride-through capability of a doubly-fed induction generator under three-phase balanced voltage sags is examined, under the condition that the machine should have the capability of real andExpand
Modelling wind farms for grid disturbance studies
This paper analyses the simplest representation of generators on wind turbine modelling, giving the accuracy required in power system disturbance studies. The order of the generator model and theExpand
Ramachandaramurthy, "Fault r ide through and voltage regulation for grid connected wind turbine
  • ScienceDirect, Renewable Energy
  • 2011
...
1
2
...