• Corpus ID: 18140570

Automated Turbidimetric Benzalkonium Chloride Method for Measurement of Protein in Urine and

@inproceedings{Ng2004AutomatedTB,
  title={Automated Turbidimetric Benzalkonium Chloride Method for Measurement of Protein in Urine and},
  author={Pak Cheung Ng and K. RossaW. and Chiu and Irene Ling Ang and Yu Kwan Tong and Enders Kai-On Ng and Frankie W. T. Cheng and Albert M. Li and Yuk Ming Dennis Lo},
  year={2004}
}
2003;21:401–7. 6. Ensenauer R, Muller CB, Schwab KO, Gibson KM, Brandis M, Lehnert W. 3-Methylglutaconyl-CoA hydratase deficiency: a new patient with speech retardation as the leading sign. J Inherit Metab Dis 2000;23:341–4. 7. Hou JW, Wang TR. 3-Methylglutaconic aciduria presenting as Reye syndrome in a Chinese boy. J Inherit Metab Dis 1995;18:645–6. 8. Jooste S, Erasmus E, Mienie LJ, de Wet WJ, Gibson KM. The detection of 3-methylglutarylcarnitine and a new dicarboxylic conjugate, 3… 

Tables from this paper

References

SHOWING 1-10 OF 23 REFERENCES
Urinary protein determination using Coomassie Brilliant Blue in the presence of sodium dodecyl sulphate.
Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.
TLDR
In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C, and the normal range for urinary protein as measured by this method was from 28 to 141 mg/day.
Assessment of the benzethonium chloride method for routine determination of protein in cerebrospinal fluid and urine.
TLDR
The linearity, sensitivity, and precision are satisfactory and the reactivity of benzethonium chloride with various proteins (albumin, immunoglobulins) is the same, but the method is unsuitable for urinary protein determination.
Evaluation of an improved Coomassie dye binding method for urinary protein assay.
  • M. Macart, L. Gerbaut
  • Biology, Medicine
    Clinica chimica acta; international journal of clinical chemistry
  • 1984
Automatic assay of urinary protein using Coomassie Brilliant Blue G-250.
A biuret method for determination of protein in normal urine.
A biuret method has been developed which provides quantitative measurements of protein in normal urine without interference from drugs or pigments. This method is intended for use in monitoring
Evaluation of the Coomassie Brilliant Blue G-250 method for urinary protein.
TLDR
In athletes and premature neonates, the Coomassie Brilliant Blue G-250 method for protein in urine has been evaluated for analytical accuracy and clinical applicability; however, the method underestimates urinary light-chain proteins.
A new micromethod for determination of protein in cerebrospinal fluid and urine.
TLDR
A new micro-scale procedure for determination of protein in cerebrospinal fluid and urine is developed, independent of temperature and albuminbinding compounds, and is not appreciably affected by the albumin—gamma globulin ratio.
New micro-turbidimetric method for determination of protein in cerebrospinal fluid and urine.
TLDR
A new micro-scale turbidimetric method for determination of protein by use of benzethonium chloride in alkali is reported, which is highly specific for protein, has a higher sensitivity than the classic method of Lowry et al., and shows satisfactory reproducibility and recovery.
...
...