Assessment of blood lactate: practical evaluation of the Biosen 5030 lactate analyzer.

@article{Davison2000AssessmentOB,
  title={Assessment of blood lactate: practical evaluation of the Biosen 5030 lactate analyzer.},
  author={R. Davison and Damian Coleman and James Balmer and Mary Nunn and Simon C. Theakston and Melonie Burrows and Steve Bird},
  journal={Medicine and science in sports and exercise},
  year={2000},
  volume={32 1},
  pages={243-7}
}
PURPOSE The aim of this study was to assess the validity and reliability of the Biosen 5030 lactate analyzer compared with a YSI 2300 lactate analyzer and a Kodak Ektachem DTII in a practical laboratory study context. METHODS To assess validity, 144 triplicate capillarized blood samples, across a range of values, were analyzed using the three analyzers. To assess reliability a further 665 samples were repeat analyzed. Temporal stability was determined by the reanalysis of resting and maximal… CONTINUE READING