A sensitive and selective method is presented to accurately determine the level of protein-bound 3-nitro-L-tyrosine (NTyr) in rat plasma and kidney samples. This assay is based on isotope dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The sample preparation entails protein precipitation, acid hydrolysis with 6 N HCl, and solid-phase extraction (using reverse and aminopropyl phase cartridges) prior to the determinative step. For… CONTINUE READING