Argon laser treatment of the anterior chamber angle for increased intraocular pressure.

@article{Pohjanpelto1981ArgonLT,
  title={Argon laser treatment of the anterior chamber angle for increased intraocular pressure.},
  author={Pirkko Pohjanpelto},
  journal={Acta ophthalmologica},
  year={1981},
  volume={59 2},
  pages={211-20}
}
Sixty-five eyes of 63 patients with increased intraocular pressure which was resistant to medical therapy were treated with argon laser and were then followed up for 3-12 months. From 70 to 110 burns were directed from 360 degrees around the chamber angle into or immediately posterior to the pigmented trabecular band. The power settings used were 1200-2200 mW, exposure time 0.1 seconds and beam diameter 50 microns. There was exfoliation syndrome in 35 eyes. Post-laser control of the intraocular… CONTINUE READING