Analysis of the glucuronidation of 7-hydroxycoumarin by HPLC.

Abstract

The in-vitro metabolism of 7-hydroxycoumarin to 7-hydroxycoumarin-glucuronide was investigated in bovine liver homogenate. A metabolic reaction mixture was prepared that included a crude preparation of uridine diphosphate (UDP) glucuronyl transferase, 7-hydroxycoumarin and UDP-glucuronic acid. A HPLC method was developed to separate coumarin, 7-hydroxycoumarin, 7-hydroxycoumarin-glucuronide and an internal standard, 4-hydroxycoumarin. Samples were separated by reverse-phase HPLC, on a C18 column, with a 1 ml min-1 gradient elution with UV detection at 320 nm. The limit of quantification of the method, for 7-hydroxycoumarin-glucuronide, was 1.47 microM, and the linear range was from 0-295.7 microM. Concentrations of 7-hydroxycoumarin-glucuronide produced were calculated from a plot of 7-hydroxycoumarin-glucuronide concentration versus the mean absorbance ratio (n = 4) (7-hydroxycoumarin-glucuronide absorbance/4-hydroxycoumarin absorbance). It was possible to monitor the decrease in the 7-hydroxycoumarin content as it was metabolised as well as the increase in 7-hydroxycoumarin-glucuronide as it was produced enzymatically. The identity of the compound produced was confirmed by photodiode array spectral analysis. A plot of time versus 7-hydroxycoumarin-glucuronide produced indicates that the metabolism is linear for the first 90 min and reached a plateau at 150 min. The rate of reaction in the first 90 min was 2.96 +/- 0.06 (RSD 1.7%, n = 3) nmol of 7-hydroxycoumarin-glucuronide produced per minute per milligram of protein. After 150 min 0.34 +/- 0.005 mM (RSD 1.4%) 7-hydroxycoumarin-glucuronide was produced, from 0.77 mM 7-hydroxycoumarin introduced into the reaction mixture and 58.0% +/- 5.3% (or 0.44 +/- 0.02 mM) of the 7-hydroxycoumarin remained. These results show that it is possible to monitor the production of the phase II metabolite of coumarin with minimal sample clean-up and without the need for deconjugation of the glucuronide moiety. The method was very reliable and applicable for the direct determination of 7-hydroxycoumarin-glucuronide in an in-vitro metabolic assay.

Statistics

0100200'06'07'08'09'10'11'12'13'14'15'16'17
Citations per Year

157 Citations

Semantic Scholar estimates that this publication has 157 citations based on the available data.

See our FAQ for additional information.

Cite this paper

@article{Killard1996AnalysisOT, title={Analysis of the glucuronidation of 7-hydroxycoumarin by HPLC.}, author={Anthony J. Killard and Richard O'Kennedy and Declan P. Bogan}, journal={Journal of pharmaceutical and biomedical analysis}, year={1996}, volume={14 11}, pages={1585-90} }