Analysis of the Ionized Field Under HVDC Transmission Lines in the Presence of Wind Based on Upstream Finite Element Method

@article{Lu2010AnalysisOT,
  title={Analysis of the Ionized Field Under HVDC Transmission Lines in the Presence of Wind Based on Upstream Finite Element Method},
  author={Tiebing Lu and Han Feng and Xiang Cui and Zhinbin Zhao and Lin Li},
  journal={IEEE Transactions on Magnetics},
  year={2010},
  volume={46},
  pages={2939-2942}
}
Corona phenomenon generated from high voltage direct current (HVDC) transmission lines can affect the environment nearby. Based on the upstream finite element method, an iterative algorithm is used to analyze the ionized electric field and the ion current density at the ground level with the wind velocity taken into consideration. The algorithm is efficiently convergent. The proposed method is testified by measurement results of a unipolar line in the presence of wind and a bipolar test line… CONTINUE READING
Highly Cited
This paper has 58 citations. REVIEW CITATIONS

Citations

Publications citing this paper.
Showing 1-10 of 23 extracted citations

Analysis of coupling characteristics of hybrid electric field in the 750kV HVAC and ± 800kV HVDC parallel transmission lines

2017 IEEE 5th International Symposium on Electromagnetic Compatibility (EMC-Beijing) • 2017
View 1 Excerpt

A Laboratory Study on the Ion-Flow Field Model of the DC Wires in Stable Wind

IEEE Transactions on Power Delivery • 2015
View 3 Excerpts

59 Citations

0102030'13'15'17'19
Citations per Year
Semantic Scholar estimates that this publication has 59 citations based on the available data.

See our FAQ for additional information.

References

Publications referenced by this paper.
Showing 1-10 of 12 references

Calculation of ION Flow Fields of HVDC Transmission Lines By the Finite Element Method

IEEE Transactions on Power Apparatus and Systems • 1981
View 5 Excerpts
Highly Influenced

and F

S. Fortin, H. Zhao, J. Ma
P. Fawalibi, “A new approach to calculate the ionized field of HVDC transmission lines in space and on the earth surface,” in Int. Conf. Power System Technology • 2006
View 1 Excerpt

Corona performance of high-voltage transmission lines [Book Review]

IEEE Electrical Insulation Magazine • 2004
View 2 Excerpts

Corona power loss, electric field, and current density profiles in bundled horizontal and vertical bipolar conductors,

Z. Al-Hamouz
IEEE Trans. Ind. Applicat., • 2002
View 1 Excerpt

Numerical analysis of ionized fields associated with HVDC transmission lines including effect of wind,

X. Li
Ph.D. dissertation, Dept. Electr. Comput. Eng., • 1997
View 1 Excerpt

Electric Fields and Ion Currents of a ?? 400 kV HVDC Test Line

IEEE Power Engineering Review • 1983
View 1 Excerpt

Similar Papers